Installation Requirements; Tools And Parts; Location Requirements; Important - Whirlpool KitchenAid KVUC600KSS0 Instrucciones De Instalación Y Manual De Uso Y Cuidado

Campana purificadora/ extractora
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
NOTE: This range hood is recommended for use with cooking
surfaces with a maximum total rating of 75,000 BTUs or less for
30" (76.2 cm) range hood and 90,000 BTUs or less for 36"
(91.4 cm) range hood.
Tools needed
Level
1
Drill with 1
/
" (3.0 cm), 3/16" (4.8 mm), 1/8" (3.0 mm), and
4
5/16" (7.9 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Metric hex key set
Parts needed
Home power supply cable
1/2" (1.3 cm) UL listed or CSA approved strain relief
3 UL listed wire connectors
1 wall or roof cap
Metal vent system
Chimney cover (optional)
Masking Tape
Parts supplied
Remove parts from packages. Check that all parts are included.
Range hood assembly with ventilator and light bulbs installed
1
3
/
" x 10" (8.3 cm x 25.4 cm) rectangular vent connector
4
2 metal grease fi lters for 30" (76.2 cm) model
3 metal grease fi lters for 36" (91.4 cm) model
T20
®
Torx
®†
adapter
4 - 5 x 45 mm mounting screws
6 - 4.5 x 13 mm screws
3 - 4 x 8 mm screws
4 - 10 x 50 wall anchors
Installation template WALL 30" and 36" models
Installation template CABINET 30" and 36" models
®
®
TORX and T20
are registered trademarks of Acument Intellectual Properties, LLC.
4

INSTALLATION REQUIREMENTS

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualifi ed technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specifi ed on the model/serial rating plate. The model/serial rating
plate is located behind the left fi lter on the rear wall of the vent
hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See the "Electrical
Requirements" section.
The Range hood is factory set for venting through the roof
or wall.
All openings in ceiling and wall where Range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Front View
2
"
(6.5 cm)
3/8 "
(1.0 cm)
7½"
(19.0 cm)
29¹ " (74.0 cm): 30" (76.2 cm) models
35¹ " (89.2 cm): 36" (91.4 cm) models
3¹ "
(7.9 cm)
30" (76.2 cm)
36" (91.4 cm)
12"
(30.5 cm)
10"
(25.4 cm)
23" (58.4 cm)
Tabla de contenido
loading

Este manual también es adecuado para:

Kitchenaid kvuc606kss0

Tabla de contenido