Terminal Assignment; Delivery Includes; Ordering Code - Kübler CODIX 52P Instrucciones De Puesta En Servicio

Ocultar thumbs Ver también para CODIX 52P:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

DC power supply:
24 V
Input level:
Standard
typ. level low:
2,5 V
typ. level high:
22,0 V
Fmax:*
kHz
ContDir/Tacho
30
UpDown/Tacho
10
Up.Up/Tacho
10
Quad 1/Tacho
15
Quad 2/Tacho
15
Quad 4/Tacho
10
Frequency measurement (INP C):
Accuracy :
< 0.1 %
Measuring principle:
< 38 Hz:
period measurement
> 38 Hz:
gating time measurement
gating time = 26,3 ms
Input sensitivity:
Standard sensitivity:
DC power supply
Low: 0 ... 0,2 x U
High: 0,6 x U
5 V sensitivity:
Low: 0 ... 2 V DC
High: 4 ...30 V DC
Pulse shape:
any*,
Schmitt-Trigger inputs
Ambient temperature:
–20 ...+65 °C
Storage temperature:
–25 ... +70 °C
EMC:
In compliance with the
EC Directive
2004/108/EEC
Noise emission
EN 61 000-6-3/
EN 55 011 Class B
Noise immunity
EN 61 000-6-2
Housing:
For front panel mounting: 48 x 24 mm
acc. to DIN 43700, RAL7021, dark gre
Weight:
appr. 50 g
Protection:
IP 65 (front)
* at maximum frequency square wave pulses 1:1
12 V 10 ... 30 V
Cleaning:
5V
The front of the units is to be cleaned only with
2,0 V
1,0 V
a soft wet (water !) cloth.
10 V
4,0 V
kHz
kHz

7. Terminal assignment

10
8
10
8
10
8
10
8
10
8
8
8

8. Delivery includes:

1 Digital display
1 Panel mounting clip
1 Bezel for screw mounting, panel cut out
1 Bezel for clip mounting, panel cut out
[V DC]
B
1 Seal
... 30 [V DC]
B
1 Multilingual operating instructions

9. Ordering code:

6.52P.012.3X0
1 10 ... 30 V DC
2 0 V GND
3 INP A
4 INP B
5 INP C
50 x 25 mm
50 x 25 mm
Input sensitivity
0 = Standard
A = 5 V
11
Tabla de contenido
loading

Este manual también es adecuado para:

Codix 54p

Tabla de contenido