REPLACING THE INTELLIBRITE POOL LIGHT CIRCUIT BOARD
When replacing the IntelliBrite Pool Circuit Board, the Unit-Tension
Wire Clamp (P/N 600095), (Gasket (P/N 79101601) or Gasket and Lens
(619864Z) MUST ALSO BE REPLACED - SEE PAGE 18 FOR PART
NUMBERS.
Removal and Installation of IntelliBrite 5G Light Circuit Board
1.
Turn off main electrical switch or circuit breaker, as well as the switch which
operates the IntelliBrite light itself.
Do not service the light while in the pool water. The light
NOTE:
MUST be serviced while on the deck.
2.
Before starting be sure that you have a new lens gasket (P/N 79101601),
Uni-Tension Wire Clamp (P/N 600095) and a IntelliBrite 5G pool light circuit
board assembly (P/N 619875Z - 300w, P/N 619916Z-400W, P/N 619917Z-
500w) - P/N 619818Z (Color) ready to install.
the same type will damage the light assembly and may cause an electrical hazard
resulting in death or serious injury to pool users, installers, or others due to
electrical shock, and may also cause damage to property.
install a new Uni-Tension Wire Clamp assembly and Lens Gasket (see page
19). Failure to do so may permit water to leak into the assembly which could
cause:
(a) an electrical hazard resulting in death or serious injury to pool users,
installers, or others due to electrical shock, or
(b) breakage of the lens, which likewise could result in serious injury to pool
users, installers, or bystanders, or in damage to property.
3.
REMOVING THE INTELLIBRITE 5G POOL
LIGHT ASSEMBLY: Remove the pilot screw
at top of face ring, remove the light assembly
from the niche. Place the assembly on the
deck. Note: It is not necessary to drain down
the pool.
4.
Unwind the cord from the base of the light
housing.
ASSEMBLY (IN AN EXISTING POOL)
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit breaker
before servicing the light. Failure to do so could result in death
or serious injury to installer, service person, pool users, or
others due to electrical shock.
Replace the light circuit board assembly with the same type and
wattage. Failure to replace the light circuit board assembly with
Always install a new Uni-Tension Wire Clamp assembly and
Lens Gasket when reassembling the light assembly Always
INTELLIBRITE
5G Pool and Spa Lights Installation and User's Guide
®
Pilot screw (bronze)
IntelliBrite 5G Pool Light
11