Viega Tempoplex 6961 Manual Del Usuario página 10

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
GB
Instructions for Use for Tempoplex Shower Drain
Use in keeping with intended purpose
The Tempoplex drain is suitable for installation in flat and superflat shower trays with
a 90 mm drain hole. Only the usual kinds of household waste water up to 95 °C may
be fed in. Feeding in other liquids is not allowed. No harmful substances are to be fed
in, such as cleaning agents which damage sanitary equipment, draining elements and
pipe materials, and particularly those with a pH value ≤4. Specialist firms should carry
out installation with consideration given to the building provisions. The shower drain
conforms to EN 274.
A
Model
Article No Available as
6961
575 601
6961.1
575 625
B
Components
Cove
C
Dimensions
D
Installation procedure
Before installation, check whether the draining rate of 0.6 l/s with a 15 mm penned-up height is sufficient.
45° drain elbow DN 40/50 is made of polypropylene (non-adhesive).
Place double seal on the
sealing surface and press
into the retaining groove.
Tighten the screws evenly.
Do not use a cordless
screwdriver.
E
Special case
If the floor of the shower
tray is thicker than 10 mm,
separate the seal.
F
Access to the drainage system (cleaning)
Make sure that the odour trap is not damaged during the cleaning process.
Remove the immersion
tube.
Insert the sealing plug flush
by hand.
518352_Tempoplex_Duschabl.indd 10
with cover with
45° draining elbow
without cover with
45° draining elbow
Immersion
Clamping collar
tube
with screw
Position drain piece with seal
under the shower tray. Guide
the upper section of the double
seal through the drain hole.
Insert immersion tube into
the water trap.
Cut above the lower sealing bead.
Remove the sealing plug by
turning gently with pliers.
Note the plug position.
Model
Article No Available as
6961.175
575 632
6961.875
575 625
Seal
10
without cover
with cover
Water trap
Screw in the fixing screws
by hand.
Press cover onto the three
attachment points.
Place the lower part on the
drain housing and the upper
part in the drain hole.
Clean the drain pipe with
an appropriate cleaning
process.
Position the immersion
tube and mount the cover
(see fig. D 6).
03.11.2011 07:19:25