Drain Stub-Out
Finished
Wall
Measure.
1. Install the Drain Body
Install the pop-up drain to the lavatory according to the
manufacturer's instructions.
Remove the inlet nut from the bottle trap body. Ensure the seal is
inside the inlet nut.
NOTICE: To ensure a proper compression fit, the tailpiece must be
inserted at least 1" (2.5 cm) inside the inlet nut.
With the threads facing down, slide the inlet nut with seal onto
the tailpiece.
Place the bottle trap body around the tailpiece, then hand-tighten
the inlet nut until the nut is flush against the bottle trap body. If
necessary, use a clean strap wrench to assist you.
NOTE: The supplied extension tube is 12" (30.5 cm) in length.
Measure the length from the drain stub-out to the inner-most
edge of the outlet nut. If the measured length is less than 12"
(30.5 cm), cut the length of the pipe using a hack saw. Be careful
not to damage the finish. If the measured length is more than 12"
(30.5 cm), a pipe of appropriate length may be purchased
separately.
Remove the outlet nut from the bottle trap body. Ensure the seal
and ring is inside the outlet nut.
NOTICE: To ensure a proper compression fit, the pipe must be
inserted at least 1" (2.5 cm) inside the outlet nut.
Kallista
To Lavatory
Flange
Tailpiece
Pipe
Inlet Nut
Outlet
Nut
Seal
Seal
Ring
3
Bottle Trap Body
1075595-2-A