Controlling Operation Via The Hood; Control Via Remote Control - THERMEx VILLA II Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

36
THERMEX CENTRALVENTILATION VILLA II
CONTROLLING VIA THE HOOD
when the hood is in use, the air extraction by the central ventilation system in the kitchen via the hood is increased. This is done by opening the
valve when the hood is in use.
when the hood is in use, the central ventilation system's forced operation is controlled by the hood's functions. You should, therefore, follow
the operating instructions for the hood.
NOTE: If a remote control for the Centralventilation Villa II is activated while the cooker hood is in use, the central ventilation system will run at
maximum speed for the time period selected on the remote control. The ventilation system will then return the cooker hood's settings.

CONTROL VIA REMOTE CONTROL

BASIC VENTILATION MODE
If the basic ventilation mode is selected on at the PCB, the system will run in the set basic ventilation mode, when neither hood or remote control
are activated. It is, however, possible to turn off the basic ventilation if it is not required. This is done using the remote control.
To disable the basic ventilation mode, forced operation should be disabled. Then the "Cancel" button should be pressed for approximately 5 sec-
onds until the basic ventilation mode turns off.
To reactivate the basic ventilation mode, forced operation must be disabled after which the "On" button is pressed for approximately 5 seconds
until the basic ventilation mode starts.
NOTE: Deactivation of the basic ventilation mode from the remote control will be reset if the power is switched off on the PCB.
FORCED OPERATION
To forced operation mode, press the "On" button. If the "On" button is pressed once, the central ventilation system will run in forced operation
mode for 30 minutes.
If the "On" button is pressed twice when activating the Centralventilation Villa II, the ventilation system will run in forced operation mode for
60 min. Similar, if you press the "On" button while the system is activated using the remote control, the ventilation system will run for 60 min.
NOTE: If the hood is in use when the remote control of the Centralventilation Villa II is activated, the central ventilation system runs at maximum
speed for the time selected on the remote control, after which the system will return to the cooker hood's settings.
The forced operation mode is disabled automatically after 30 or 60 min., depending on how the system has been activated, but if you want to
disable the system, before that time has elapsed, pressing the "Cancel" button returns the ventilation system to the basic ventilation mode or
to the hood's settings if the hood is enabled.
NOTE: If several remote controls are connected to the Centralventilation Villa II, forced operation mode is disabled, regardless of the remote
control on which "Cancel" is pressed.
One or more remote controls can be used for the Centralventilation
Villa II. One of these is always included when the system is pur-
chased.
when the buttons on the remote control are activated a small red
diode at the top of the remote control lights up in the middle of
the words Villa ventilation. This indicates that the remote control is
transmitting a signal.
when the remote control is activated, the central ventilation sys-
tem's forced operation runs at max. speed.
NOTE: If several remote controls are connected to the Centralventi-
lation Villa II, the system is controlled by all of the remote controls.
It does not, therefore, matter which of the remote controls are used
to activate/deactivate the system.