Reset Master Code (If The Previous One Is Forgotten) - Fermax Memokey 100 códigos Manual De Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Reset Master Code (in case previous code is forgottenr)
This operation is done by electrical manipulation of the equipment, to ensure the
impossibility of modification by anyone without physical access to the same.
1. Disconnect the system power supply.
2. Make a short circuit between terminals "Bs" and "-" of the equipment.
If the system has an exit pushbutton, simply keep it pressed.
3. Reconnect the power supply and remove the short circuit (or release the exit
pushbutton). You have 20 seconds to enter a new MASTER Code (the system expects
as many digits as are programmed in the "Code length (A4)" function).
NOTE:
Resetting the MASTER Code does not delete the rest of the information
programmed in the system.