WIRING DIAGRAM

1
2
3
4
5
6
9
7
8
A
0
B
Memokey connections:
Exit pushbutton (Bs, -): Lets you open the door with the same timing as programmed for access
(1 to 99 sec). Contact normally open.
Open door sensor (Sp, -): To determine if the door stays open for longer than the time permitted
(1 to 99 sec.).
Exit pushbutton (Bs, -): Lets you open the door with the same timing as programmed for access
(1 to 99 sec). Contact normally closed.
AUX: Auxiliary output providing a maximum current of 125 mA (0V) to connect/activate another device
(auxciliary relay, alarm ...) or a loudspeaker so that Memokey can set off an alarm tone (the other end of the
speaker must be connected to a positive power supply).
Note: Use an electric lock/door release suitable for the power supply to be used (Vac or Vdc).

TECHNICAL FEATURES

Power supply: 9 to 15 Vdc/Vac.
Operating temperature: 0 to 70º C.
Capacity: 100 access codes.
Consumption:
* In standby:
* With open door relay active:
Brown
Red
'C'
Orange
'NO'
Yellow
'NC'
Green
'Sp'
Violet
'Bs'
Blue
'AUX'
Grey
20 mA.
70 mA.
SEC 12Vac/dc
PRIM 230V
12 Vac / 12 Vdc
POWER
SUPPLY
OPEN DOOR DETECTOR
(optional)
EXIT PUSHBUTTON
(optional)
DOOR RELEASE
(max. 2A)