Fermax Memokey 100 códigos Manual De Usuario página 23

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Enable auxiliary exit - AUX (A6)
This equipment has an auxiliary output (earth connection: 0V) that provides a maximum
current of 125 mA in order to connect/activate another device (auxiliary relay, alarm...) or a
loudspeaker so that the Memokey generates its own alarm tone.
If the equipment to be connected does not fit these specifications, a relay must be used
(Ref. 2013).
To enable/disable this function:
With the AUX output activated, these three functions can be carried out:
-
After 5 wrong codes are entered, the AUX output is activated for the time set in
the "Auxiliary output timing (A7)" option, indicating that someone is trying out
some codes. If the value of A7 is 00, nothing is indicated.
-
If the tamper (in the Memokey) detects module opening, the AUX output is
activated, indicating an alarm for the time set in the "Auxiliary output timing (A7)"
option.
If A7=00, an alarm tone will be generated for 20 seconds, and can directly
activate a loudspeaker (where the other end has to be connected to a positive
power supply (depending on this power source, the use of a limiting resistance
in series with the loudspeaker is recommended).
-
If the coaction mode is activated (activated by entering 'A plus valid Code') the
AUX output is activated, indicating alarm for the time set in the "Auxiliary output
timing (A7)" option. If A7=00, an alarm tone will be generated for 20 seconds,
and can directly activate a loudspeaker, as explained above.
If the door sensor detects an unauthorised open door, the AUX output is activated,
-
indicating alarm for the time set in A7. If A7=00, an alarm tone will be generated
for 20 seconds, and can directly activate a loudspeaker, as mentioned.
-
If the door opening has been authorised and it remains open for more than the
time set in the "Door sensor timing (A8)" option, the AUX output is activated in
the same way.
1º Enter the programming mode:
2º Key in option:
3º Key in "1" to enable the button
Key in "0" to disable it:
Example:
Enable auxiliary exit
Master Code (1480)
A6
1: Enabled
0: Disabled
1480 A6 1
beep (x4)
beep (x4)
beep (x4)
Pag 9
Tabla de contenido
loading

Tabla de contenido