Flue Pipe Dimensions; Connection To The Flue Pipe - de manincor CLASSIC F40 Instrucciones De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FLUE PIPE DIMENSIONS

Guideline for sizing the flue as a function of it's height:
FLUE PIPE (h)
< 4m
4m < 6m
> 6m
If this is not feasible you should contact a flue specialist.
CROSS-SECTION: the flue pipés cross-section depends on
the height of the flue and the thermal power of the installed
cooker.
To ensure the optimal yield of our cookers we recommend
you use circular flue pipe with smooth interior lining and of
the same length all the way up.
INSULATION: flue draught pressure also depends on the dif-
ference in the temperature of the hot flue gases and that of
the air outside.
The flue pipe must be insulated to restrict absorption of heat
into the walls and therefore avoid condensation, which can
cause tarry residues. Use only suitable heat- and corrosion-re-
sistant materials conforming to building and fire-prevention
regulations. You should not use flue pipes comprising simple
or flexible metal tubes, cement tubes for vents, etc.
DEPRESSION: the optimal depression (flue draught pressu-
re) for DeManincor's cookers is 0,12 mbar.
At a depression below 0,12 mbar, the fire will burn too slowly
and form carbon residue excessive gases. If instead depres-
sion is any greater, combustion will be too fast and not tran-
smit as much heat to the oven and the heating plate.
FLUE PIPE DIMENSIONS
Draw not guaranteed
Ø 160 mm
Ø 150 mm
a
a.
Flués refractory
interior lining or
b
stainless steel
(min.T400)
b.
Prefabricated
c
external casing
c.
Insulation material

CONNECTION TO THE FLUE PIPE

The cooker is delivered with the connection corresponding to
the flue exit chosen when ordering:
Above
Fix
Rear
Fix
Side
Telescopic
EACH COOKER SHOULD HAVE ITS OWN FLUE PIPE. DO
NOT USE THE SAME FLUE PIPE FOR MORE THAN ONE
APPLIANCE.
THE COOKER SHOULD BE CONNECTED TO THE FLUE PIPE
AVOIDING AS FAR AS POSSIBLE ANY BENDS,
DIVERSIONS AND DOWNWARD OR HORIZONTAL
SECTIONS.
1. Pipe is too long and
on inclined plane
2. Pipe narrower than outlet hole
3. Leaky cleaning panel
NO
1
2
3
Connecting pipes must be perfectly sealed to each other and
to the stove and flue pipe. These precautions must be taken:
• use a seal to avoid infiltration of air into the flue;
• the pipe must not be narrower at the end;
• the end of the pipe must not protrude into the flue.
NO
8
Cast Iron
Ø 130 mm
Cast Iron
Ø 130 mm
Steel
Ø 130 mm
4. Sealed connections
5. Inspection
6. Cleaning
5
4
6
NO
NO
Pipe too
Unsealed
far in
connection
YES
YES
correct
connection
Tabla de contenido
loading

Productos relacionados para de manincor CLASSIC F40

Tabla de contenido