GENERAL
Although all gas connections on the grill are leak
tested at the factory prior to shipment, a complete gas
tightness check must be performed at the installation
site due to possible mishandling in shipment, or
excessive pressure unknowingly being applied to the
unit. Periodically check the whole system for leaks
following the procedures listed below. If the smell of
gas is detected at anytime you should immediately
check the entire system for leaks.
BEFORE TESTING
Make sure that all packing material is removed from
the grill including tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING.
NEVER PERFORM LEAK TEST WITH AN OPEN
FLAME.
Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush, or
rag to apply the solution to the fittings. For the initial
leak test, make sure the L.P. cylinder is 80% full.
TO TEST
1.
Make sure the control valves are in the "OFF"
position, and turn on the gas supply.
2.
Check all connections from the LP gas regulator
and supply valve up to and including the
connection to the manifold pipe assembly (the pipe
that goes to the burners). Soap bubbles will appear
where a leak is present.
3.
If a leak is present, immediately turn off the gas
supply and tighten the leaky fittings.
4.
Turn the gas back on and recheck.
5.
Should the gas continue to leak from any of the
fittings, turn off the gas supply and contact
customer service at 1-800-913-8999.
Only those parts recommended by the manufacturer
should be used on the grill. Substitution will void
the warranty. Do not use the grill until all
connections have been checked and do not leak.

Leak Testing

GAS FLOW CHECK
Each grill burner is tested and adjusted at the factory prior
to shipment; however, variations in the local gas supply
may make it necessary to adjust the burners. The flames
of the burners should be visually checked.
Flames should be blue and stable with no yellow tips,
excessive noise or lifting. If any of these conditions exist,
check to see if the air shutter or burner ports are blocked
by dirt, debris, spider webs, etc. If you have any questions
regarding flame stability, please call customer service
1-800-913-8999.
ALWAYS CHECK FOR LEAKS AFTER EVERY
L.P. TANK CHANGE
Check all gas supply fittings for leaks before
each use. It is handy to keep a spray bottle of
soapy water near the shut-off valve of the gas
supply line. Spray all the fittings. Bubbles
indicate leaks.
GENERAL USE OF THE MAIN BURNER
Each main burner is rated at 15,000 BTU/hr. The main
grill burners encompass the entire cooking area and are
side ported. The igniter knobs are located on the lower
center portion of the valve panel. Each rotary igniter is
labeled on the control panel.