PROBLEM
1. Compressor will not start with
initial pressure.
2. Compressor gets excessively
hot.
3. Compressor keeps on releasing
air when stopping use.
4. Compressor generates too little
air
5. Safety valve is dripping

TROUBLESHOOTING

CAUSE
Overload protector activated
Tank with pressure
Motor broken down
Damaged pressure switch
Overload protector activated
Loose cable
Switch would not release air circuit
Voltage drop in the line
Defective retention valve
Dirty air filter
Defective valves
Condensation-water drain nozzle is
open
Pressure is too high
Defective safety valve
*TASC: Truper Authorized Service Center®
SOLUTION
Restore the protector
Discharge
Go to the nearest TASC*
Go to the nearest TASC*
Turn off the compressor and wait
for it to cool, then work it again. If
the fault persists go to TASC*
Discharge
Go to the nearest TASC*
Go to the nearest TASC*
Do not use extension cables
Go to the nearest TASC*
Clean / replace filter
Go to the nearest TASC*
Close nozzle
Go to the nearest TASC*