Warranty
The warranty period is two years and covers manufacturing defects. The warranty is valid on condition that the machine is used in
the normal way and receives the required service. Normal wear and tear is not covered. Repairs must be carried out by
Dustcontrol or personnnel authorized by Dustcontrol. Otherwise, the warranty is void.
Troubleshooting
Problem
The drive unit does not
suck or does not suck
enough.
The drive unit runs, but no
suction.
The drive unit runs, but
poor suction.
Machine blows dust.
Abnormal sound from
machine.
EC Declaration of Conformity
We hereby declare that DC 5900 TR is in compliance with the following regulations and standards: 2006/42/EC, 2014/35/EU,
2014/30/EU, EN 60204-1, EN 1822-1.
The serial number and year of manufacture are indicated on the rating plate of the machine.
Dustcontrol AB
Anna-Lena Berg / CEO
2019-05-07
Cause
Compressed air not connected or poor
main pressure.
Suction hose not connected.
Hose blocked.
No plastic bag in cyclone.
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Filter loose or damaged.
DC 5900, Art.nr. 9458-F
Solution
Check the compressed air pressure at the
machine during operation. Pressure should
be at least 6 bar.
Connect hose.
Reverse or clean hose.
Insert a plastic bag.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Check and replace as necessary.
Book service.
Peter Söderling / Technical Manager
19