CHOOSING THE LOCATION OF THE GAS GARDEN FIREPLACE.
The gas garden fireplace is a mobile appliance capable of movement to any place of your choice. Ho-
wever, there are restrictions that must be strictly followed. The appliance, due to the possibility of high
temperatures on its external surfaces, should be kept away from flammable materials, and also due to
the open combustion chamber without the possibility of connecting to chimney flues, it should be
used in open spaces or in well-ventilated rooms. IT IS ABSOLUTELY PROHIBITED to place the appliance
in a position other than horizontal.
Tips for proper and safe installation of the appliance:
• Connect the regulator to a cylinder or a household liquid gas installation, so that the valve does
not affect the horizontal position of the furnace with its other components. Connecting it in any
other way may block the gas supply to the device. To do this, use the appropriate tools. Tightening
the regulator by hand is insufficient and may result in gas leakage. Cylinder replacement and / or
connection should take place in well ventilated areas.
• Make sure that the rubber gaskets are in place and undamaged before connecting the gear unit. If
this is not the case, the device cannot be used until the seal has been replaced.
• Remember that the gas cylinder should always be in an upright position and the hose connecting
the cylinder to the burner should be laid in such a way that it does not come into contact with sharp
objects or edges, as well as hot elements of the burner.
• Check the correctness and tightness of the installed gas control control system and the entire gas
system of the device. To do this, you can use soapy water or a dedicated spray to detect gas leaks. To
check for leaks, cover with water and soap or spray any connections (cylinder- regulator, regulator -
gas hose, gas hose - controller gas block, gas block - copper wires for the magnetos and main burner,
main burner nozzle - copper wire) between the cylinder and the controller and those behind the gas
block, and then ignite the device so that the gas also fills the section from the gas block to the burner
nozzles. If bubbles appear on the joints, it means that there is a leak in this place.
ATTENTION!
Safe distances from flammable materials that should be kept in accordance with the instructions in
this manual have been established on the basis of safety tests. Flammable materials can be called
anything that can catch fire, i.e. paper, wood, all kinds of fuels, plastic, clothing, etc. The designated
space is not limited by non-flammable materials, but also applies to flammable materials directly
behind non-flammable objects exposed to contact with device.
If you are unsure of the flammability of any material within the device, consult your fire brigade.
Remember that fireproof materials are considered flammable despite their fire resistance. They can
be difficult to set on fire, but they also burn.
REQUIREMENTS FOR GAS GARDEN FIREPLACE FOR FREE SPACE OF FLAMMABLE MATERIALS
AROUND THE APPLIANCE AND MINIMUM SAFETY DISTANCES OF THE FIREPLACE FROM THE
COUNTER EDGE LINE IN WHICH IT IS INSTALLED.
The gas garden fireplace has been tested and approved for heating open or well ventilated spaces,
subject to safe distances from flammable materials, as shown in the diagrams below.
EN
27