Part 3
ELECTRICAL CONNECTIONS
3
ELECTRICAL CONNECTION
REQUIREMENTS
This appliance must be installed and grounded on a
branch circuit by a qualified technician in accordance
with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.
All wiring should conform to Local and NEC. This
range requires a single-phase, 3 wire, A.C 120/208V or
120/240V 60Hz electrical system. Use only a 3-conductor
or a 4-conductor UL-listed range cord with closed-
loop terminals, open-end spade lugs with upturned
ends or similar terminations. Cord must have the
strain relief properly installed.
A range cord rated at 40 amps with 120/240 minimum
volt range is required. If a 50 amp range cord is used,
it should be marked for use with 1
connection openings.
This appliance may be connected by means of conduit
or power cord. If conduit is being used, go to page 6
3 wire conduit connections or page 7 for 4 wire
conduit connections.
WARNING
New branch-circuit installations (1996 NEC), mobile
homes, recreational vehicles, and installations
where local codes do not allow grounding through
neutral require a 4-conductor UL listed range cord
or 4 wire conduit connection.
4
CONNECT RANGE CORD
The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block
will then be accessible.
3
⁄
" diameter
8
4
3, 4 - Wire electrical wall Receptacle types
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Conduit connection plate is used for the installation of
power cord or conduit. For power cord, install it with
conduit connection plate as manufacturer supplied.
For conduit cord, remove the conduit connection plate
located below the rear of the drawer body and use the
conduit hole (1
1
/
") instead of power cord hole (1
8
(Refer to Figure 8.)
Specified power-supply-cord kit rating
Range rating, watts
Specified rating
of power-supply-
120/240 volts
120/208 volts
cord kit, amperes
3-wire
3-wire
8,750 - 16,500
7,801 - 12,500
16,501 - 22,500
12,501 - 18,500
FIGURE 3
FIGURE 4
Diameter (inches) of Range
connection Opening
Power cord
40 or 50A
1
3
/
"
8
1
/
"
50
3
8
3
/
").
8
Conduit
1
1
/
"
8
1
/
"
1
8