Alcad TCB-040 Manual Del Usuario página 8

Sistema de videoportero con pulsadores
Ocultar thumbs Ver también para TCB-040:
Tabla de contenido
VIDEOPORTERO ELECTRÓNICO - VIDEODOOR ENTRY SYSTEMS - VIDÉOPORTIER ÉLECTRONIQUE
INSTALACIÓN CON 2 ACCESOS - INSTALLATION WITH 2 ACCESS POINTS - INSTALLATION AVEC 2 ACCÉS
ESQUEMA UNIFILAR - SINGLE-WIRED DIAGRAM - SCHÉMA À UN FIL
SECTION TABLE
Up to 25 m -
Up to 100 m -
Use separate cable hose.
Section according to the number of monitors/telephones in the dwelling.
Funcionamiento - Operation - Fonctionnement
SYSTEM ON STAND-BY
The functions of door opening and of communication with the entrance panel are disabled. It is possible to activate the monitor's
automatic switch-on system always providing that the system is not engaged (Maximum time setting for the auto switch-on system:
30 seconds).
SYSTEM ACTIVATED. MAKING A CALL
Only the monitor associated to the pushbutton will receive the call. Acoustic confirmation for the visitor. The system does not permit
any other monitor to use the auto switch-on function.
Time setting to answer: 30 seconds.
Maximum time setting for conversation: 60 seconds. Extension of time for conversation: + 60 seconds.
During the time settings to answer and for conversation, all other entry panels are deactivated. In this case the red light of these
panels will flash.
DIV-034
T1
+
T1
T1
T1
+
T1
+
T1
T1
+
T1
T1
+
T1
T1
+
T1
DIV-034
T1
+
T1
T1
T1
+
T1
+
T1
T1
+
T1
T1
+
T1
T1
+
T1
TWISTED PAIR