DRAINAGE

During the process of cooling, some water will be extracted from the air into the unit.
If the reservoir is full, both of the compressor and motor will stop and the units would
buzz (you can press any button to stop the buzz). The W.F. indicator will flash to show
you.
To make the cooling work again, please empty the water by one of the following ways:
1. Turn off the air conditioner and avoid moving it when full.
2. Position a container (a water tray for example) underneath the drain hole.
3. Remove the drain knob & rubber plug from the drain hole and allow the water to
drain out.
4. When the container is almost full, replace the rubber plug in the drain hole and
empty the water tray.
5. Repeat until the unit is emptied.
6. Replace the rubber plug and tighten the drain knob firmly.
7. Switch on the unit - the full water or compressor operating indicator should not be
flashing.