Ocultar thumbs Ver también para 400 Serie:
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Installation Guide
for Andersen
400 Series Tilt-Wash Double-Hung Picture Windows
®
with Stormwatch
Protection (PG Installation)
®
Thank you for choosing Andersen.
Instructions are for typical, new wood-framed wall construction with weather protection in place.
Instructions may not be right for all installations due to building design, construction materials or methods used and/or building or site
conditions. Consult a contractor or architect for recommendations.
Flanges on the unit alone will not properly flash and seal the window. Follow these instructions carefully.
For questions call 1-888-888-7020 Monday - Friday, 7 a.m. to 7 p.m. and Saturday, 8 a.m. to 4 p.m. central time.
For more information and/or guides visit
Please leave this guide with building owner.
▶ ▶ Read▶guide▶from▶beginning▶to▶end▶before▶starting▶installation.▶Read▶all▶warnings▶and▶cautions▶during▶unit▶installation.▶▶
▶ ▶ Important▶Safety,▶Assembly,▶and▶Installation▶Information: Impact Resistant Glass used by Andersen is not hurricane proof or shatter proof,
and may not offer a high level of security. Proper installation of window and door units with impact resistant glass is as important to product
performance as the glass.
Use caution when working at elevated
heights and around unit openings. Follow
manufacturers' instructions for ladders and/or
scaffolding. Failure to do so may result in injury
or death.
Accessories such as grilles, art glass, and insect screens may dislodge and become airborne if window/door is impacted by wind borne debris from
severe storms or hurricane strength winds. In the event of a storm, remove all accessories from windows/doors and move to a safe location. DO
NOT stand in front of or near windows/doors.
Unless specifically ordered, Andersen windows
and doors are not equipped with safety glass,
and if broken, could fragment causing injury.
Many laws and building codes require safety
glass in locations adjacent to or near doors.
Andersen windows are available with safety
glass that may reduce the likelihood of injury
when broken. Information on safety glass is
available from your local Andersen dealer.
"Andersen" and all other marks where denoted are trademarks of Andersen Corporation. ©2005-2010 Andersen Corporation. All rights reser ved.
and e rs e nw i nd ow s .co m .
Follow manufacturers' instructions for hand
or power tools. Always wear safety glasses.
Failure to do so may result in injury and/or
product damage.
• Andersen
Head Flashing and Installation Flanges DO NOT take the place of standard window
®
and door flashing. Unit must be properly flashed and sealed with silicone for protection
against water and air infiltration. Use non-reflective flashings. Highly reflective flashing tapes
can raise the surface temperature of the vinyl to the point where vinyl deformation and product
damage may occur.
• Do not apply any type of film to glass. Thermal stress conditions resulting in glass damage
could occur.
• Use of movable insulating materials such as window coverings, shutters, and other shading
devices may damage glass and/or vinyl. In addition, excessive condensation may result
causing deterioration of windows and doors.
Windows and doors can be heavy. Use safe
lifting techniques and a reasonable number
of people with enough strength to lift, carry
and install window and door products to
avoid injury and/or product damage.
0 00 5 1 2 6 B B
Revised 07/13/10
Tabla de contenido
loading

Resumen de contenidos para Andersen 400 Serie

  • Página 1 In addition, excessive condensation may result causing deterioration of windows and doors. “Andersen” and all other marks where denoted are trademarks of Andersen Corporation. ©2005-2010 Andersen Corporation. All rights reser ved. 0 00 5 1 2 6 B B...
  • Página 2 Personal injury, product and/or property damage may occur. • Support or Stormwatch Joining Kit must be used when joining Stormwatch Protection units. Check for availability with your local Andersen dealer. ® • If Optional Stool or Sill Extension Jambs are to be...
  • Página 3 Installation Guide 2. Prepare Unit • Remove unit from packaging. Place unit interior side up on a clean, flat work surface. • Remove wood/foam packaging blocks and staples Installation Flanges are factory applied to fit 4-1/2" Protection Blocks wall thickness. Installation Flanges may be Interior Side Up reversed to fit 4-1/8"...
  • Página 4 Installation Guide 2. Prepare Unit (continued) Head Jamb Screw Hole The number of installation screws required is Head Liner based on the maximum unit PG rating specified. Use correct number of screws and spacing. Screw Hole Side Jamb • Remove Head Liner, Side Jamb Liners, and Sill Trim Side Jamb Piece.
  • Página 5 Installation Guide Andersen 400 Series Tilt-Wash Double-Hung Picture Window Screw Location Chart ® UNIT UNIT UNIT SCREWS PER SCREWS PER UNIT UNIT UNIT SCREWS PER SCREWS PER NAME WIDTH HEIGHT HEAD/SILL JAMB SIDE NAME WIDTH HEIGHT HEAD/SILL JAMB SID DHP10310 12"...
  • Página 6 Installation Guide 3. Apply Extension Jambs Finish Nail Extension Extension Jamb Application BEFORE Installation Jamb (Side) (all Extension Jamb sizes) Extension Jamb (Sill) • Ripping of Extension Jambs may be required to fit End Fastener nonstandard wall depths. (Before Installation) •...
  • Página 7: Install Unit

    Installation Guide 4. Install Unit • Apply 1/4" bead of sealant, full perimeter, to back side of Installation Flange or full perimeter around rough Installation Flange opening, 1/2" from edge. Sealant Caulk Gun Metal fasteners and other hardware components may corrode when exposed to preservative treated and fire-retardant treated lumber.
  • Página 8 Installation Guide 4. Install Window Unit (Continued) • Measure across head, center, and sill of unit. Tape Measure Center dimension should match head and sill dimensions. Shim to straighten Side Jamb, if necessary, by inserting shims at midpoint Installation behind the Side Jamb between unit frame and Flange rough opening.
  • Página 9 Installation Guide 6. Apply Flashing Tape Unit must be properly flashed and sealed for protection against water and air infiltration. Use non-reflective flashings. Highly reflective flashing tapes can raise the surface temperature of the vinyl to the point where vinyl deformation and product damage may occur. •...
  • Página 10 • If optional Sill Stop, Stool or Sill Extension Jambs are to be Casing used refer to their specific instruction guides available at your Andersen Dealer. Install on unit before Interior Casing. Side Jamb When applying Interior Casing, carefully read and follow directions and illustrations below.
  • Página 11 Andersen local. “Andersen” y las demás marcas que aparezcan son marcas registradas de Andersen Corporation. ©2005-2010 Andersen Corporation. Todos los derechos reservados. 0005126 BB Revisado 13/07/10...
  • Página 12: Herramientas Y Suministros

    • Jambas de extensión • Rejillas NO colocar objetos/accesorios en la unidad a menos • Juegos de unión que sean productos Andersen especialmente ® diseñados para la unidad. Pueden provocarse lesiones personales y/o daños a la propiedad o al producto.
  • Página 13: Prepare La Unidad

    Guía de instalación 2. Prepare la unidad • Reitre la unidad del embalaje. Coloque la parte interior de la unidad hacia arriba sobre una superficie de trabajo plana y limpia. • Retire las grapas y los bloques de embalaje de madera/espuma Bloques de protección...
  • Página 14 Guía de instalación 2. Prepare la unidad (continuación) Jamba de cabecera Orificio de tornillo La cantidad requerida de tornillos de instalación se Revestimiento de cabecera basa en la máxima clasificación PG de la unidad especificada. Utilice la cantidad correcta de Orificio de tornillo tornillos y espacios.
  • Página 15 Guía de instalación Cuadro de ubicación de los tornillos para ventanas panorámicas, inclinables de limpieza, de guillotina doble, de la serie 400 de Andersen ® NOM. DE LA AN. DE LA ALT. DE LA TORNILLOS POR TORNILLOS NOM. DE LA AN.
  • Página 16: Coloque Las Jambas De Extensión

    Guía de instalación 3. Coloque las jambas de extensión Jamba de Clavos de acabado extensión Aplicación de jambas de extensión ANTES de la (lateral) instalación Jamba de (todos los tamaños de jambas de extensión) extensión (riel inferior) Sujetador de extremos (antes •...
  • Página 17: Instale La Unidad

    Guía de instalación 4. Instale la unidad • Aplique un cordón de 1/4" de sellador en todo el perímetro, en la parte posterior de la brida de Brida de instalación instalación o alrededor de toda la abertura no acabada Sellador Pistola para a 1/2"...
  • Página 18: Asegure La Unidad A Través De Las Jambas

    Guía de instalación 4. Instale la ventana (continuación) • Mida a lo largo de la cabecera, el centro y el Cinta métrica riel inferior de la unidad. La dimensión del centro debe coincidir con las dimensiones de la cabecera y del riel inferior. Coloque cuñas para Brida de enderezar la jamba lateral, si fuera necesario, en instalación...
  • Página 19: Aplique La Cinta De Flashing

    Guía de instalación 6. Aplique la cinta de flashing La unidad debe estar instalada con flashing y sellada de manera adecuada para protegerla contra la filtración de agua y aire. Use flashing no reflectante. Las cintas de flashing altamente reflectante pueden aumentar la temperatura de la superficie de vinilo hasta el punto en que se puede producir deformación del vinilo y dañar el producto.
  • Página 20: Coloque La Moldura Interior (Proporcionada Por Terceros)

    Jamba lateral disponibles a través de su distribuidor Andersen. Instale sobre la unidad antes de la moldura interior. Al aplicar la moldura interior, lea y siga cuidadosamente las instrucciones e ilustraciones que se encuentran a continuación.

Tabla de contenido