• An inner cable conductor
diameter greater than 1.2 mm,
or the presence of burrs may
damage the sockets on the
unit.
Technical Data
Type
Order no.
Subscriber connections
Inputs
Frequency ranges
Connection loss ¹
)
Decoupling horiz./vert.
Decoupling subscribers
Max. operational level ²
)
System example (symbolic representation)
Quatro feed
Quatro-
system
Speisesystem
Sat-IF
950-2,150
**) Overvoltage protector KAZ 11/KAZ 12
Electronic equipment is not household waste - in accordance with directive 2002/96/EC OF THE EUROPEAN
PARLIAMENT AND THE COUNCIL of 27
be disposed of properly. At the end of its service life, take this device for disposal at a designated public col-
lection point.
Internet: www.kathrein.de
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 • P.O. Box 10 04 44 • 83004 Rosenheim • GERMANY • Phone +49 8031 184-0 • Fax +49 8031 184-306
EXR 58/ECO
20510051
8
4 x
1 x terr.
Sat-IF
MHz
5-862
950-2,150
dB
15 → 17
5 → 0
dB
-
25
dB
40
25
dBμV
-
111
th
(danger of overwinding)
Type
Control input vert./horiz.
Control low/high band
Max. total remote feed current ³
Permissible ambient
temperature
Connections
Dimensions (W x H x D)
Packing unit/weight
¹
Frequency-dependent attenuation (pre-emphasis)
)
²
SAT acc. to EN 60728-3, 35 dB IMod
)
³
Via horizontal low input
)
January 2003 on used electrical and electronic equipment, it must
936.3790/-/ZWT/0810/e - Technical data subject to change!
EXR 58/ECO
V
12-14.5/16-19
kHz
0/22
)
mA
350
°C
-20 to +55
F-type connectors
mm
162 x 148 x 43
pc./g
1 (10)/490