Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

INSTALLATION INSTRUCTIONS
E-WPS Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
4.
SUITABLE FOR MOUNTING WITHIN 1.2m (4ft) OF THE
GROUND
PEUT ETRE INSTALLE A MOINS DE 1,2 m (4 pi) DU
SOL.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
NOTES:
1. Fixture is only intended to be mounted with the light facing
downward. Do NOT mount as an uplight.
www.e-conolight.com
|
LPN00684X0001A0_A
Document:
Created By:
TMT
JUNCTION BOX MOUNTING
NOTE: Knockouts in mounting base allow for mounting over a
31/2" or 4" octagonal junction box, a 4" square junction box, a
masonry box, a 4" round box, or a single gang box. Junction
boxes must be at least 1/2" deep for proper installation of fixture.
1.
Remove the mounting base from the fixture by loosening (do NOT
fully remove) the one or two (depending on fixture size) mounting
base screws on the bottom of the fixture and lifting the fixture off
the base. See Figure 1.
2.
Refer to Figure 2 on next page to determine the correct holes to
knock out for mounting over the junction box being used.
3.
Route the supply leads from the junction box through the hole
locations in the center plug in the mounting base. Push one wire
through each opening in the plug.
4.
Align the holes in the mounting base will the screw boss locations
on the junction box. Make sure rib on outer edge of mounting base
is facing upwards. Attach the mounting base to the junction box
using screws provided by others. See Figure 3 on next page.
NOTE: The bubble level inside the mounting base should be used
to ensure a level install of the fixture.
5.
For hands free wiring, position the fixture housing on top of the
mounting base by inserting the rib on the mounting base into the
slot on the top of the fixture. See Figure 3 on next page.
6.
Make wiring connections per Fixture Wiring section.
7.
Lift fixture housing off mounting base and rotate housing so that
slot in fixture housing is facing upward.
8.
Insert rib on upper edge of mounting base into slot on top of
fixture.
9.
Push lower edge of fixture against mounting base and tighten
one or two (depending on fixture size) mounting base screws on
the bottom of the fixture to retain the fixture against the mounting
base.
10. A high grade caulking material, such as silicone rubber, should
be used where the mounting base meets the mounting surface to
ensure a watertight seal. Make sure that caulk is applied around
the entire perimeter of the mounting base. See Figure 4 on next
page.
FIGURE 1
888.243.9445
|
FAX: 262.504.5409
Date
ECO#
WPS01 & WPS03
One Screw
WPS05 & WPS08
Two Screws
3-9-2020
011592
Fixture
Base
Fixture
Base
loading

Resumen de contenidos para e-conolight saVr E-WPS Serie

  • Página 1 PEUT ETRE INSTALLE A MOINS DE 1,2 m (4 pi) DU SOL. SAVE THESE INSTRUCTIONS WPS05 & WPS08 FOR FUTURE REFERENCE Fixture NOTES: 1. Fixture is only intended to be mounted with the light facing downward. Do NOT mount as an uplight. Base Two Screws www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 2 Do NOT apply paints, solvents, or any other chemicals to the light fixture because these substances could cause premature deterioration of the finish. FIGURE 4 Do NOT spray the fixture with a high pressure washer. Mounting Base www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 3 Tuck all wires carefully into wiring chamber ensuring that no wires required to correct the interference at his own expense. are pinched. CAN ICES-005 (A)/NMB-005 (A) www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 4 PEUT ETRE INSTALLE A MOINS DE 1,2 m (4 pi) DU SOL. WPS05 Y WPS08 CONSERVE ESTAS INSTRUCCIONES PARA Luminaria CONSULTAS POSTERIORES NOTAS: Base 1. La luminaria está diseñada para instalarse únicamente con la luz orientada hacia abajo. NO la instale orientada hacia arriba. Dos tornillos www.e-conolight.com 888-243-9445 FAX: 262-504-5409...
  • Página 5 NO use limpiadores abrasivos o que contengan alcohol. NO aplique pintura, disolventes u otros productos químicos a la luminaria, ya que estas sustancias podrían provocar deterioro prematuro del acabado. NO rocíe la luminaria con un lavador de alta presión. FIGURA 4 Base de montaje www.e-conolight.com 888-243-9445 FAX: 262-504-5409...
  • Página 6 (blanco). 3. Conecte el cable L2 (vivo) del suministro al cable vivo de la luminaria (negro). Acomode cuidadosamente todos los cables en la caja de conexiones y asegúrese de no aplastar ningún cable. www.e-conolight.com 888-243-9445 FAX: 262-504-5409...
  • Página 7: Mesures De Sécurité Importantes

    REMARQUES : 1. Le luminaire est uniquement destiné à être monté avec la lumière Base dirigée vers le bas. NE l'utilisez PAS en tant que luminaire à éclairage dirigé vers le haut. Deux vis www.e-conolight.com 888 243-9445 TÉLÉC. : 262 504-5409...
  • Página 8 N'appliquez PAS de peintures, de solvants ou d'autres produits chimiques sur le luminaire, car ces substances pourraient Base de montage entraîner une détérioration prématurée de la fi nition. Ne vaporisez PAS le luminaire avec un nettoyeur haute pression. www.e-conolight.com 888 243-9445 TÉLÉC. : 262 504-5409...
  • Página 9 (blanc) de l’appareil. 3. Raccordez l’alimentation L2 (sous tension) au fil sous tension (noir) de l’appareil. Insérez soigneusement tous les fils dans la chambre de câblage en vous assurant qu'aucun fil n'est coincé. www.e-conolight.com 888 243-9445 TÉLÉC. : 262 504-5409...

Este manual también es adecuado para:

Savr wps01Savr wps03Savr wps05Savr wps08