e-conolight E-FCB Serie Instrucciones De Instalación

e-conolight E-FCB Serie Instrucciones De Instalación

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
E-FCB and E-FFB Series
1/2" FITTER
TRUNNION
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
YOKE
2" FITTER
www.e-conolight.com
|
Document:
LPN00548X0001A2_A
Created By:
TMT
MOUNTING USING 1/2" FITTER
NOTE: Fixture can be mounted to any metal 1/2" NPSM threaded
mounting (supplied by others).
NOTE: When mounting the fixture in an inverted position (1/2" fitter
above fixture), mount fixture to a watertight junction box and cover.
Also, caulk the conduit openings, around the junction box cover, and
the wire entry end of the 1/2" fitter with a high grade caulking material,
such as silicone rubber, to ensure water does not enter fixture through
1/2" fitter.
1.
Route fixture leads through hole in mount.
2.
Thread mounting onto end of fitter on fixture and secure with
locknut. Using thread sealant on the threads will ensure a
watertight seal.
Wire as indicated in Electrical Connections section.
3.
4.
Aim fixture by loosening screw on knuckle of fitter and rotating
fixture to desired tilt angle. Re-tighten screw.
MOUNTING USING YOKE
1.
Mount fixture using (2) 1/4" (6 mm) fasteners appropriate for
mounting surface. Slots in base of yoke can be used as a template
for locating holes in mounting surface.
2.
Aim fixture by loosening screws on sides of yoke and rotating
fixture to desired tilt angle. Re-tighten screws.
3.
Route cord from fixture to junction box where supply leads can be
accessed. Seal entry of cord into junction box.
4.
Wire as indicated in Electrical Connections section.
MOUNTING USING TRUNNION
1.
For E-FFB08 and E-FFB11 fixtures mount using (2) 1/4" (6 mm)
fasteners and washers appropriate for mounting surface. For
E-FFB18 and E-FFB23 fixtures use (2) 3/8" (10 mm) fasteners
and washers appropriate for mounting surface. Slots in base of
trunnion can be used as a template for locating holes in mounting
surface.
2.
Remove locking screw on side of trunnion.
3.
Loosen hex head bolts on sides of the trunnion.
4.
Rotate trunnion to desired tilt angle. Line up inner and outer
trunnion locking holes.
5.
Insert locking screw, removed in Step 2, into matching holes of
inner and outer trunnion. Tighten screw.
6.
Securely tighten both hex head bolts on sides of trunnion.
7.
Wire as indicated in Electrical Connections section.
MOUNTING USING 2" FITTER (E-FFB08 AND
NOTE: Fixture is intended to be mounted on 2-3/8" (60 mm) O.D.
heavy wall pipe or tenon.
1.
Pull supply leads through end of mounting pipe or tenon.
2.
Wire cord leads exiting bottom of 2" fitter to supply leads as
indicated in Electrical Connections section.
3.
Insert splices and cord into open end of mounting pipe or tenon.
4.
Slip lower fitter over pipe or tenon, being careful not to pinch any
leads.
5.
Aim fixture by rotating on pipe or tenon to desired direction.
Securely tighten (2) Allen set screws on fitter to 140 in-lbs
(16 N•m).
6.
Loosen (DO NOT remove) Allen head bolt holding two halves of
fitter together. Tilt fixture to desired angle. Tighten bolt to
132 in-lbs (15 N•m).
888.243.9445
|
FAX: 262.504.5409
Date
7-02-2019
ECO#
010778
E-FFB11)
Tabla de contenido
loading

Resumen de contenidos para e-conolight E-FCB Serie

  • Página 1 Adspte pour les Endroits Mouiles. (16 N•m). Loosen (DO NOT remove) Allen head bolt holding two halves of SAVE THESE INSTRUCTIONS fitter together. Tilt fixture to desired angle. Tighten bolt to 132 in-lbs (15 N•m). FOR FUTURE REFERENCE www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 2: Fcc Notice

    1. Connect supply ground to fixture ground (green) lead. 2. Connect supply L1 (Hot) to fixture neutral (white) lead. 3. Connect supply L2 (Hot) to fixture hot (black) lead. Tuck all wires carefully into wiring chamber ensuring that no wires are pinched. www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 3: Medidas De Seguridad Importantes

    Afl oje (SIN retirar) el tornillo Allen que sujeta las dos mitades del acoplador. Incline la luminaria según el ángulo deseado. Apriete el tornillo con un par INSTRUCCIONES PARA de apriete de 132 lb-pulg. (15 N•m). CONSULTAS POSTERIORES www.e-conolight.com 888-243-9445 FAX: 262-504-5409...
  • Página 4: Conexiones Eléctricas

    (blanco). 3. Conecte el cable L2 (vivo) del suministro al cable vivo de la luminaria (negro). Acomode cuidadosamente todos los cables en la caja de conexiones y asegúrese de no aplastar ningún cable. www.e-conolight.com 888-243-9445 FAX: 262-504-5409...
  • Página 5 Desserrez (NE PAS retirer) le boulon à tête hexagonale qui maintient ensemble les deux moitiés du montant. Inclinez le luminaire à l’angle désiré. RÉFÉRENCE ULTÉRIEURE Serrez l’écrou à 15 N m (132 lb-po). www.e-conolight.com 888 243-9445 TÉLÉC. : 262 504-5409...
  • Página 6: Raccordements Électriques

    (blanc) de l’appareil. 3. Connectez L2 (sous tension) au fil sous tension (noir) de l’appareil. Insérez soigneusement tous les fils dans la chambre de câblage en vous assurant qu’aucun fil n’est coincé. www.e-conolight.com 888 243-9445 TÉLÉC. : 262 504-5409...

Este manual también es adecuado para:

E-ffb serie

Tabla de contenido