at the warm stop limit), or 3°C colder (on the cold stop limit), as required for a good
operation of the mixer (see page 16, bottom par.).
3.5.2 Quantity counting error
After pressing START, after around 12 seconds this wording appears:
Possible causes:
A) If no water comes out of the device:
The taps on the inlets of warm water and/or cold water are not open. Check that both
are open and that the connection to the pipes is correct.
The inlet filters are obstructed. Clean them.
The electrovalve does not open. Contact the Service.
B) If water comes out normally and this message appears, it indicates a malfunction of the
litre-counter. Contact the Service.
3.5.3 Probe error
The PrE wording appears on the display referred to the damaged or wrongly connected probe.
Contact the Service for replacement. If the external probe is damaged, the wording appears,
but the machine works properly. On the contrary, if the internal probe is damaged, the by-pass
is controlled for a few seconds, then it shifts automatically to the dosing: the by-pass
thermostatic control is excluded. Use the external probe to check that the temperature is
correct.
3.5.4 Tension fall
If there is a tension fall during a water delivery, the device stores the delivered quantity and
interrupts the delivery. When tension is restored, the following wording appears:
Press START to complete the dosage.