Pressing the 1 key, the wording diS appears, indicating that the recipe programming is disabled;
pressing the 2 key, the wording Abi appears, indicating that the recipe programming is
enabled.
Pressing P the normal visualization is restored.
Free delivery: it is possible to exclude the litre-counter counting (for example in case of
malfunction of the part) by means of the special program P99:
With the START and STOP keys the electrovalve opens and closes.
3.5 ERROR MESSAGES AND CORRECTIVE ACTIONS
All error messages are accompanied by flashing wordings and an intermittent acoustic
signalling. The latter one can be stopped with the STOP key. Using the START key the error
message is cancelled and the delivery starts again. On the contrary, the double STOP
command cancels the delivery. The possible error messages and relevant wordings are listed
here below.
3.5.1 Unreachable temperature
With the by-pass electrovalve open, if the temperature stabilizes at a value outside of the
allowed tolerance range, after 30 seconds the following menu appears:
Possible causes:
A) The regulation of the temperature by means of the knob is not correct. Regulate the
temperature.
B) The regulating knob is at one limit stop, but it is not enough to reach the set temperature
value. Check that the water is at least 10°C warmer than the requested value (if the knob is
DOMIX 45 A – 2600111 – 11.09.2001