Indoor Unit Fixing - Toshiba RAS-M22NKCV Serie Manual De Instalación

Tabla de contenido

Indoor Unit Fixing

1. Pass the pipe through the hole in the wall and hook the indoor
unit on the installation plate at the upper hook.
2. Swing the indoor unit to right and left to confirm that it is firmly
hooked up on the installation plate.
3. While pressing the indoor unit onto the wall, hook it at the lower
part on the installation plate. Pull the indoor unit toward you to
confirm that it is firmly hooked up on the installation plate.
1
2
Hook 
For detaching the indoor unit from the installation plate, pull the
indoor unit toward you while pushing its bottom up at the
specified parts.
Push
Hook here.
1
 Installation plate
Press
(unhook)
Push
Drainage
1. Run the drain hose sloped downwards.
NOTE
The hole should be made at a slight downward slant on the
outdoor side.
Do not rise the
drain hose.
50 mm
or more
Do not put the
drain hose end
into water.
2. Put water in the drain pan and make sure that the water is
drained out of doors.
3. When connecting extension drain hose, insulate the connecting
part of extension drain hose with shield pipe.
Shield pipe
Drain hose
Inside the room
CAUTION
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed to drain water
collected from dew, which forms on the back of the indoor unit,
to the drain pan. Therefore, do not store the power cord and other
parts at a height above the drain guide.
Space for pipes
Do not form the
drain hose into
a wavy shape.
Do not put the
drain hose end
in the drainage
ditch.
Extension drain hose
Wall
Drain guide
Tabla de contenido