NETWORK ANALYZER DESCRIPTION
The Wallbox solution of reference 0600582-039 includes a three-phase network
analyzer that complies with the Sub Meter requirements defined in ITC-BT 52
have the ability to measure active and reactive energy, being Class 1 (kWh)
according to standard EN62053-21 and of Class B (kWh) according to standard
EN50470-3, with a 0.5 kWh resolution and certified according to the MID
international standard for legal metrology, referring to the active electrical
energy meters. It can be used for tax metrology (legal).
This three-phase energy analyzer includes a backlit LCD display with integrated
8 digit keypad, with is particularly useful for the measuring of active energy in
applications up to 65 A (direct connection) with dual-rate management
availability.
You can measure the energy consumed and generated or it can be programmed
to only count the energy consumed.
The meter is supplied with the output pulses proportional to the active energy
being measured, Modbus RS 485 port which permits integration with the
electronic Wallbox charge manager and/or with external applications for.
Tracking consumption and charge time of the electric vehicle and detecting
possible anomalies in the electricity network in terms of levels and surges and
overages.
Single-phase power supply
Maximum current (measured)
Minimum current
Protection Index
Dimension
External communication
Display
Resolution
Working frequency
Operating temperature
DISPLAY READING INSTRUCTIONS
The display is divided into 3 display lines. The engineering units are referred to
the variable shown in the relevant display line. The "negative" symbols (·, dmd)
refer to all the displayed variables. To improve the display legibility, the EM24
uses some symbols. In case of "OVERFLOW", the instrument displays "EEEE": at
the same time the DMD calculation, the hour-counter and the energy meters
functions are inhibited and the alarm outputs are activated. The indication
"EEEE" in a single phase variable automatically implies the overflow condition
of the relevant system variable, and the PF indication is forced to "0.000".
The LCD Display has cursors to scroll in the Measuring or Programming Menus
and has UP and DOWN cursors, which enable you to switch the measuring
mode of the readings from instantaneous values to cumulative values with
the following parameters: Energy Consumed (kWh+), Power (kW), Voltage (V),
Current (A), Power Factor (FP), Frequency (Hz), kvarh+, kvarh-, kW dmd, kW
peak dmd.
230Vac +/- 30% (Self-powered)
Up to 65A
50mA
IP50
4T
Modbus RTU (Slave function)
8 digit LCD
0,5 kWh
45 / 65 Hz
-25Cº - +55ºC
1. Joystick
To program the configuration parameters and view the pages of the measured
variables on the display.
2. LED
The flashing red LED is proportional to the measured energy (kWh).
3. Display
LCD-type with alphanumeric indications to:
- display the configuration parameters;
- display all the measured variables.
4. Selector
To select the desired display pages and block programming.
5. Connections
Screw terminal blocks for instrument connections.
INSTRUCTION OF USE OF NETWORK ANALYZER
Nombre y descripción del menú
Entering the right password allows accessing the main
PASS?
menu.
CnG PASS
It allows changing the password.
APPLiCAt
It allows selecting the pertinent application.
It links an ID code to the user of the displayed consumption
USEr
(Three 1-phase independent users by instrument).
It allows selecting the measuring page to be displayed
SELECtor
according to the knob position.
SYS
It allows selecting the electrical system.
Ut rAtio
VT ratio.
Ct rAtio
CT ratio.
It is the integration time used to calculate the demanded
P int.ti
powers.
diG in 1/ diG in 2/
It allows defining the digital inputs function.
diG in 3
duP in
Digital input connected to channel A5.
Number of counters transmitted by means of Dupline from
duP Cnt
0 to 6 tiplexer address of the first counter.
Number of the analogue variables transmitted by means of
duP AnA
Dupline from 0 to 8.
duP out. 1/ duP
Alarm function is active only for applications C, E, G and H.
out. 2
It allows selecting the operating range of the digital filter as
FiLtEr.S
% of the full scale value.
FiLtEr.Co
It allows selecting the filtering coefficient.
EnE t.rES
It allows the reset of all the total counters.
To go back to the measuring mode press the joystick in
End
direction 1. Joystick in directions 4 and 5 allows browsing
the programming menu again.
6
Rango
-
-
-
From 1 to 9999
SELEC. 1 (2, 3, LoC)
3P.n; 3P; 3P.1; 2P; 1P
1,0 to 6000
1,0 to 60,00k
1 to 30 min
GAS; Cold; Hot; kWh+Hot;
PrESCAL.1 (ó 2 ó 3) (de 0,1 a
999,9)
no; SYnC; tAr
Adr Cnt; rES Cnt; duP Cnt.n
Adr AnA; duP AnA.n
yes; on AL; off AL; t dEL
1 to 100
1 to 32
-
-