LIFT CORPORATION Sht. 16 of 56 DSG#
24. Remove plastic nut from lock valve
(FIG. 16-1). Then, ensure valve is
closed to locked (reset) position by
turning lock valve shaft fully clockwise
(FIG. 16-1).
25. Lower and remove fl oor jack (FIG. 16-2).
© MAXON Lift Corp. 2017
M-15-13
Rev. C Date: 12/13/17
ENSURING LOCK VALVE IS CLOSED
FIG.
JACK REMOVED
FIG. 16-2
16-1