Before Operation - Mestra R-110300 Manual Del Usuario

Ocultar thumbs Ver también para R-110300:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

BEFORE OPERATION

▪ Before using this item check each part is undamaged.
Check all pipes are firmly connected. Inspect the air
receiver (tank) to ensure that it has not been
damaged.
▪ Save major packaging for return of product in the
event of service or repair.
▪ Before using the air compressor please check that
you have a suitable electrical supply to support the
requirements of the motor unit. Please ensure your
mains power supply corresponds to the power rating
on the data label on the machine.
▪ Ensure that all cables are damage free before
connecting to the power supply
▪ Use an extension cable, which is no more than 10
metres long and has a conductor cross-section of at
least 1.5 mm2. Using an excessively long or thin-
wired extension cable will cause severe damage to
the motor. Always fully unwind extensions cables. If
using extension cables outdoors always use a cable
which is marked for outdoor use.
▪ It is very important that the compressor is positioned
so that there is an adequate airflow around the
machine. The compressor should be situated so that it
has 50 cm of obstacle free space around its air
receiver (tank) and pump/motor unit.
▪ For the correct function and longevity of your air
compressor it is important that the air, which is
drawn into the compressor is clean. The compressor
should not be used in an area, where the air is
contaminated with dust.
▪ Ensure that the compressor is placed on ground,
which is flat and does not have an incline greater than
15 º. If the compressor is placed at an angle greater
than 15 º in any direction, damage to the pump unit
will result.
▪ Operating the compressor without the air filter will
cause severe damage to the pump unit.
INSTALACIÓN
1. The machine should be operated in the room with
temperature of 5-40 ºC and relative humidity of
greater that 80%. Surrounding area of the machine
should be clean, dry, free of corrosive gas, well
ventilated and not direct sunlight.
Note: Special power line for the machine is
recommended with short circuit protection and reliable
grounding device.
2. After unpacking check the machine for any missing
parts and damages, check accessories and spare parts
and technical document supplied together with the
machine.
3. Connection of air pipes: connect air supply pipe with
the quick coupling.
4. Check if switch is "OFF".
5. Electrical connection: check if power supply is
normal. Insert the plug for the machine into power
supply socket. Installation of the machine is
completed.
6. Remove the plug closing the air
inlet and place the filter in that
hole (using the compressor
without the filter could
seriously damage the motor).
TEST RUN OF THE MACHINE
1. Close drain valve and air supply value. Check if the
reading of pressure gauge is below 6 bar. Turn the
operation switch to "ON", the machine will start
immediately. The reading of pressure gauge will
slowly rise with increasing pressure inside the air
tank. When the reading of pressure gauge reaches 8
bar, pressure switch activates, the power supper is
cut off, machine stops running.
2. During the period when the machine stops running
observe if the reading of pressure meter is
decreasing. If there is no leakage of air in the
machine, open air supply valve to begin supply of
compressed air. When the pressure in the air tank
decreases to 6 bar, pressure switch resets and power
supply resumes, the machine starts running again.
The pressure in air tank increases again. If the
machine can automatically stop and start, the
machine works normally.
3. Turn the operation handle for pressure switch to
"off" position (Switch off position), then pull out the
plug of the machine. Test run is completed.
OPERATION
1. To operate ther compressor correctly and safely read
carefully this operation instruction.
2. Insert the plug of the machine in power socket of 230
V, 50/60 Hz. Open ball valve, turn the operation
handle for pressure switch to "ON" position, the
machine will run in a normal condition.