CLEANING
▪ Clean the items with a soft brush or a wiper
moistened with a suitable biodegradable solvent.
▪ Do not use inflammable liquids like petrol or alcohol,
they are a fire risk and will damage the finish and
plastic parts.
▪ Ensure that the cooling fins on the pump body are
kept clean. Fins heavy with dust have poor cooling
properties and the compressor will over heat and
damage will occur.
FAULTS
▪ Have the air compressor repaired by a competent
person.
▪ Use only genuine replacement parts, which are
available from the authorized dealer or distributor.
▪ Do not use modified or non-genuine parts.
▪ Do not use the air compressor with damaged parts,
before further use a damaged air compressor must be
carefully checked by a qualified person to determine
that it will operate properly. Check for breakage of
parts, mountings and other conditions that may
affect its operation. An authorised service centre
should properly repair a damaged part, unless
indicated otherwise in the instruction manual.
TRANSPORTATION AND
STORAGE
The machine should be transported and stored in
following condition:
▪ Ambient temperature: -40 ºC ~ 55 ºC
▪ Relative humidity: 80 %
▪ Atmosphere pressure: 500 Hpa-1060 Hpa
TECHNICAL SPECIFICATION
Voltage:
Power:
Aspirated air:
Effective airflow (4 bares):
R.p.m.:
Noise:
Pressure:
Tank capacity:
Weight:
Height:
Width:
Depth:
10
R-110300 / R-110310
230 V, 50/60 Hz
750 W
152 l/min
80 l/min
1400
58 dB
6-8 bar
38 L
30 / 37 kg
650 mm
390 mm
390 / 540 mm
MAINTENANCE
▪ Maintain air compressor with care
▪ Keep the air compressor clean for better and safer
performance.
▪ Follow instructions for changing accessories.
▪ Inspect the air compressor and extensions
cables/hoses occasionally; have them repaired
by a qualified person or authorised service body.
Every 40 minutes, the dryer solenoid valve activates to
release air and water.
Draining of air tank
The frequency for draining is depend on environment
condition and operation time, but usually once every 2-3
days. The way to drain off the condensate is as follows:
Put the drain pipe connecting drain valve quick coupling
in a container. With compressed air in the air tank,
slowly turn counter-clockwise the knob on the drain
valve to drain off the water in the air tank until all
accumulated water comes out from the pipe. After that
turn tightly clockwise the knob to ensure no leakage.
Change of filter
An air filter is installed on air inlet of the air compressor
to prevent the dust in the air from entering the air
compressor and reduces noise. After used for a period of
time the filter core in the air filter will get clogged. In a
result sucking capacity of the air compressor will be
reduced, therefore the filter core must be replaced
regularly. The way of replace is as follows: open the lid
on the air filter, take out the old filter core, put in a new
one, and then close the lid.
R-110330 / R-110340
230 V, 50/60 Hz
1500 W
230 l/min
160 l/min
1400
59 dB
6-8 bar
60 L
58 / 66 kg
750 mm
680 mm