Chart 2:Superduty 5 and Truant 2 Boots Type Examination Test Results According to EN 13634:2015
Technical Standard
Test
Unit
Reference
Upper
Impact
EN 13634:2015 Section
seconds
abrasion
4.4.4
resistance
Impact cut
EN 13634:2015 Section
mm
resistance
4.4.5
Sole
Transverse
EN 13634:2015 Section
kN
rigidity of
6.1
footwear
06
Superduty5&Truant2BootCEManual.indd 6-7
Requirement
Area A: (Achilles' and instep)
Level 1: ≥ 1.5 s
Level 2: ≥ 2.5 s
Area B: (Remainder of boot upper)
Level 1: ≥ 5 s
Level 2: ≥ 12 s
Upper is classified based on the lowest result obtained in either area A or
B. For a definition of Area A and B see Fig. 1 and Chart 3.
Area A: (Achilles' and instep)
Level 1: ≤ 25 mm maximum knife penetration
Level 2: ≤ 25 mm maximum knife penetration
Area B: (Remainder of boot)
Level 1: ≤ 25 mm maximum knife penetration
Level 2: ≤ 15 mm maximum knife penetration
Upper is classified based on the lowest result obtained in either area A or
B. For a definition of Area A and B see Fig. 1 and Chart 3.
Level 1: ≥ 1.0 kN
Level 2: ≥ 1.5 kN
Fig. 1
Result
Y
Level 1
X
2
Chart 3: Dimensions for Material Areas shown in Fig.1
Level 1
" F "
Size
Size
(Paris Points)
(English)
Minimum (mm)
38 and Below
5 and below
40
39-42
5.5 to 8
50
43 and above
8.5 and above
55
The lower tangent of Zone 2 is used to define the lower limits of measure-
Level 1
ment F & G. Zone 2 is located by centering point X over the natural center of
the ankle as felt through the footwear when worn.
KEY
1
Zone 1 Shin Region
1
2
Zone 2 Ankle Region
Area A
Area B
Keys for F and G
See Chart 3
" G "
Maximum (mm)
120
125
130
07