NOTICE TO INSTALLER: Instructions must remain with installation.
Your Peace of Mind is Our Top Priority
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
ZOELLER DOUBLE PIGGYBACK VARIABLE LEVEL FLOAT SWITCH
Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A separate branch circuit is
recommended, sized according to the National Electrical Code for the current shown on the pump name plate.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps
are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong
grounded receptacle. If the installation does not have such a receptacle, it must be changed to the proper type, wired and grounded in accordance with
the National Electrical Code and all applicable local codes and ordinances.
Zoeller 10-0229, 10-0230, 10-1209, 10-1210, 10-1964, 10-1965, 10-1966 and 10-1967 Double Piggyback Variable Level Float Switches are
CAUTION
designed for use with the appropriate voltage and horsepower, nonautomatic, single phase Zoeller pumps.
Use 10-0229, 10-1209, 10-1964 and 10-1966 for 115 V and 10-0230, 10-1210, 10-1965 and 10-1967 for 230 V. All can be used as a control
CAUTION
switch for a magnetic or combination starter. Maximum temperature must not exceed 140 °F (60 °C). NOTE: UL recognized and CSA approved. NOTE: Consult
factory for controlling units over 1-1/2 HP with variable level float switch.
FIGURE 1
CORDS SECURED
TO DISCHARGE
"ON"
LEVEL
FLOAT
CLAMPS
"OFF"
LEVEL
INSTALLATION INSTRUCTIONS
1.
Determine the desired pumping range for your installation (see Figure 1). Secure the float cable clamps to the discharge pipe at the distance you desire
(See clamp detail in Figure 6 on next page). The float labeled "TOP" must be on top. The cable clamps are releasable, which permits readjustment and
removal. NOTICE: Do not adjust "Off'' level below discharge of pump.
INSTALLATION INSTRUCTIONS CONTINUED ON NEXT PAGE
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
10-0229, 10-1209 10-1964, 10-1966 - 115 V / 1 HP - 15' (5 m) cord
10-0230, 10-1210, 10-1965 and 10-1967 - 230 V / 2 HP - 15' (5 m) cord
Designed for EFFLUENT, SEWAGE AND DEWATERING applications.
READ ALL INSTRUCTIONS BEFORE INSTALLING - ALL APPLICATIONS
PIPE
NARROW
ANGLE
FLOAT
SWITCHES
© Copyright 2017 Zoeller
®
CORDS SECURED
TO DISCHARGE
PIPE
"ON"
LEVEL
FLOAT
CLAMPS
"OFF"
LEVEL
THE "OFF" LEVEL IS
APPROXIMATELY
4" (101 mm) BELOW
MOUNTING LOCATION
MECHANICAL FLOAT SWITCH
10-1964, 10-1965, 10-1966, 10-1967
Co. All rights reserved.
®
1
visit our web site:
www.zoeller.com
THE "ON" LEVEL IS
APPROXIMATELY
4" (101 mm)
ABOVE MOUNTING
LOCATION
SECTION: 6.10.110
FM0478
0317
Supersedes
0812
SK308B