Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe AXOR Uno 38225000 Modo De Empleo/Instrucciones De Montaje

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The mixer can not used together with a continuous
flow water heater.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,25 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 33)
Flow diagram
(see page 33)
Rate of flow mixer
Rate of flow handshower
Adjustment (see page 34)
Set hot water limiter
Operation (see page 35)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Due to the design of the Bidette fittings, a
small amount of water will leak at the outlet
of the fitting when the hand shower is run-
ning.
Cleaning (see enclosed brochure)
Spare parts (see page 36)
Test certificate (see page 32)
Tabla de contenido
loading

Tabla de contenido