Warning: Danger due to high voltage!
Even in disconnected condition the inverter can re-
tain high voltages, which is a major shock hazard .
Therefore:
Be very cautious when working with the inverter
P P
and wires!
After switching off the inverter as well as before
P P
working on the inverter, make sure to regulate
the time intervals as recommended by the man-
ufacturer so that the high voltage components
can be discharged!
Make sure to adhere to the assembly regulations
of the inverter manufacturer!
Warning: Danger due to electric arc!
The solar modules generate a direct current when
exposed to light . When opening a closed circuit,
e .g . disconnecting the direct current wire from the
loaded inverter, a fatal electric arc may occur .
Never disconnect the solar generator from
P P
the inverter while the inverter is connected
to the grid!
Make sure to use only flawless wire connec-
P P
tions! Connect wires seamlessly and keep
them free from dirt!
Electrical Installation
The solar modules are designed for use in PV
systems of application class A and are approved
for operation in systems with dangerous direct cur-
rent (more than 120 V DC in accordance with EN
61730) and power . PV modules of this application
class are approved for operation in installations
with unrestricted access . Centrosolar AG modules
of this class, which are qualified under EN 61730
and have been properly installed, meet the re-
quirements of protection class II .
18
Transport, temporary storage
and safe unpacking
The modules are sensitive technical components,
which must be handled with utmost care . There-
fore, be particularly careful during transport and
temporary storage and leave the modules in the
package until they are used . Always lift and carry
the module with both hands and never carry by
means of the junction box .
Do not drop the modules or place them down
clumsily on a hard floor and/or on the module
corners. Do not place any objects on the mod-
ules. Do not stack the modules without protec-
tion.
Avoid deflection of the modules. Do not walk
on the modules. Do not treat with sharp ob-
jects and keep all electrical contact areas clean
and dry.
For documentation purposes, the serial number
should be noted . If required, the modules should
be temporarily stored in a dry, ventilated room .
Please pay special attention to the warnings
on the package as well as on the enclosed un-
packing instructions!