INTRODUCTION
The R-100006 is an electronic spatula for wax modelling specially designed to be used by professionals
in the field of dental prosthesis. Its ergonomics, easy handling and small size make it an ideal element
for this kind of work. The high accuracy of the electronic controls allows to maintain the temperature of
the spatula tip within a narrow error range. The working temperature is shown in the digital display in the
control box.
It is an ideal device to be attached to a parallelometer or similar device for wax modelling. The device is
factory supplied with a Ø2, Ø2.35 or Ø3 mm fixing shaft. It includes a set of 4 different tips.
INSTALLATION
Place the control box (B) on a flat, horizontal and firm surface, away from vibration or heat sources.
•
Make sure it is away from flammable materials.
Select one of the tips (H) and screw it into the adaptor (A).
•
Fit the adaptor to a parallelometer, micro-milling support, etc, and fix it to the shaft (G).
•
Connect the plug (C) to the control box.
•
Connect the unit to a grounded 230 V, 50/60 Hz power source.
•
OPERATION
Turn on the main switch (F) in the right side of the control box (B).
•
Press the qp keys (D) to select in the display (E) the temperature you wish for the tip to reach.
•
After finishing the work, disconnect the device by turning off the main switch (F), and handle the tip
•
very cautiously for several minutes until it has cooled down completely.
MAINTENANCE AND CLEANING
To ensure a long working life of the device and an optimum performance, we strongly recommend:
Remove the wax remains from the device periodically. To do this, you can use a small spatula. Do
•
not forget to disconnect the device beforehand.
Do not spill melted wax over the casing of the device. Handle the spatula with caution.
•
SPECIFICATIONS
Voltage:
Power:
Fuse:
Temperature range:
Height x width x depth (control):
Fixing shaft:
Height of adaptor:
Weight of control box:
230 V, 50/60 Hz
12 W
1 A
50 ~ 200 ºC
65 x 75 x 120 mm
Ø 3 / 2.35 / 2 mm
23 mm
650 g
English
7