English
1
User instructions
Valve terminal type CPA...-ASI-4E4A-Z has been designed
exclusively for controlling pneumatic actuators and is only
suitable for use in bus systems in accordance with the
AS-Interface specifications. If additional commercially-
available components such as sensors and actuators are
connected, the specifiedlimits for pressures, tempera-
tures, electrical data, torques, etc. must be observed.
Valve terminal type CPA...-ASI-4E4A-Z enables 4 valve
solenoid coils and 4 sensors to be controlled.
AS-Interface bus systems and valve terminals may only be
installed by personnel especially trained for this purpose.
Detailed information on the design and addressing of your
bus system can be found in the manual for your AS-Inter-
face master.
Detailed information on the pneumatic components of the
valve terminal can be found in the Pneumatics manual
P.BE-CPA-... .
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Commission only a valve terminal which has been
fitted and wired completely.
S Switch on the power supply only if the DIL switch is
positioned at a permitted setting. Only the DIL switch
settings listed under section 3.1 are permitted.
Festo CPA...-ASI-4E4A-Z 1108a English
17