Seal Unit- Assembly/ Disassembly; Preperation; Assembly/ Disassembly - Wangen XPRESS 64 Instrucciones De Operación

Idiomas disponibles

Idiomas disponibles

Chapter: Maintenance and repair

Seal unit- Assembly/ Disassembly

4.2

4.2.1 Preperation

4.2.2

4.2.3 Assembly/ Disassembly

DANGER!
Danger of beeing pulled in by accidental restarting the pump.
Death or serious bodily injury.
• Remove the connection for the power supply
• Lock the main switch
4-6
Seal unit- Assembly/ Disassembly
Personal protective equipment:
- Safety goggles
- Security shoes (steel toed)
- Gloves
Tools:
- Combination wrench for M8, M12 (1/4"), M16 (3/8")
- Slotted screwdriver 6,5mm x150mm (2x)
- crane
- Round sling (1x)
1. Before starting work, Ensure the absence of voltge and secure it against
inadvertent reconnection.
2. Remove the screw connection (1192)(1193) at the tension ring (1191).