Start Up
Operation
• Close the product outlet (K).
• Double check all connections are correctly secure and the
tank cover and fill up cap are securely closed.
• Turn on the air compressor and allow it to fill up.
• Regulate the compressor air outlet from 45 PSI to 100 PSI.
• Open the air outlet of the compressor towards the paint
tank.
• Wait for the tank to fill up and adjust the paint tank
regulator until the gauge shows 25 PSI to 60 PSI.
• Use the hand crank to mix the product.
• Open the product outlet and start spraying.
K
Cleansing
• Once the job is finished, to stop and clean the system
follow the following procedure:
• Turn off the compressor and close the air inlet to the
paint tank.
• Turn the tank regulator (L) in a counterclockwise
direction until stooping to feel the spring tension.
CAUTION
make sure is safe to open the tank.
• Close the product outlet (K).
• Remove the cover locks and open the tank. Remove the
product bucket and empty the remaining product on an
adequate container.
• Remove the nozzle and the sprinkler from the spray gun.
• Again, turn on the compressor. Open the air outlet to the
paint tank.
• Point the spray gun to the inside of the container where
A
the remaining product vas poured. Press the trigger to
empty the paint hose.
• Turn off the compressor and close the air outlet to the
paint tank.
• Clean the spray gun, the product container bucket and
the tank cover, paying special care with the inside, the
washers, the filter and the rotor. Make sure all the
accessories in the tank, the regulator, the valve, the paint
hose and the spray gun components are free of hardened
material that could obstruct the air flow.
• Once the components are clean, pour a little amount of
solvent into the paint bucket. Set the bucket in the tank.
L
Set the cover and close it again with the four safety locks.
• Turn the tank regulator (L) clockwise until feeling the
spring pressure.
• Turn on the compressor again. Open the air outlet
towards the paint tank.
• Point the spray gun to an adequate container to dispose
of the material. Spray until clean solvent is coming out
through the spray gun.
• Turn off the compressor and close the air outlet to the
paint tank.
CAUTION
and the compressor with their respective pressure release
valves.
• Open the tank cover to allow the solvent to dry.
• Pull the pressure release ring (A) to
• Release the pressure in the paint tank
9
ENGLISH