PROGRAMMING AN ACCESS KEY USING THE MASTER CARD
OPERATION
Enter the programming mode
Place the desired badge or keychain in front of
the module
Place the next badge or
keychain to be programmed
in front of the module
Or:
Exit the programming mode
PROGRAMMING AN ACCESS KEY USING THE PROGRAMMER Art.1028
OPERATION
Enter the programming mode
Scroll the menu using the UP or DN buttons
till option: Add Card.
Press OK to select
Insert the fist 10 digits written
on the lower right corner of the badge
or "00" followed by the 8 digits
at the center of the keychain
and press OK twice
ignore the digits after the
comma on the badge
Exit the programming mode
DELETING ALL ACCESS KEYS USING THE TERMINAL BOX
OPERATION
Connect terminal GND to terminal CLR
for 2 seconds
DELETING AN ACCESS KEY
OPERATION
Enter the programming mode
Scroll the menu using the UP or DN buttons
till option: Del Card.
Press OK to select
Insert the fist 10 digits written
on the lower right corner of the badge
or "00" followed by the 8 digits
at the center of the keychain
and press OK twice
ignore the digits after the
comma on the badge
Exit the programming mode
6
FT CA 02
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The buzzer will "bip" continuously for 2
seconds
The buzzer will "bip" continuously for 2
seconds
The buzzer will "bip" continuously for 2
seconds and will return automatically in
standby mode
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The programmer requires to insert the number
of the card or keychain to be registered
The buzzer will "bip" continuously for 2
seconds if the card or keychain has been
accepted
Or
The buzzer will "bip" twice if the access key is
already stored in memory
The buzzer will "bip" continuously for 2
seconds and will return automatically in
standby mode
DESCRIPTION
The buzzer will "bip" for a variable time,
according to how many access keys are stored
in memory (Max 8 min), and will return
automatically in standby mode.
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The programmer requests the number of the
access key that is to be deleted
The buzzer will "bip" for 2 seconds if the
access key is deleted
Or:
the buzzer will "bip" twice if the access key is
not stored in memory
The buzzer will "bip" continuously for 2
seconds and will return automatically in
standby mode
DELETING ALL ACCESS KEYS USING THE PROGRAMMER Art. 1028
OPERATION
Enter the programming mode
Scroll the menu using the UP or DN buttons
till option: Del All
Press OK to select
Insert the first 10 digits written
on the lower right corner of the Master Card
and press OK twice
ignore the digits after the
comma on the badge
Exit the programming mode
CHANGING THE MASTER CARD USING PROGRAMMER Art. 1028
OPERATION
Enter the programming mode
Scroll the menu using the UP or DN buttons
till option: ChgMcard.
Press OK to select
Insert the password 6789 and
press OK twice
Place the desired master card in front of the
module *
* If no card is placed in front of the module within 60 seconds, it automatically returns to
standby mode
CHANGING THE ADMINISTRATOR PASSWORD
OPERATION
Enter the programming mode
Scroll the menu using the UP or DN buttons
till option: ChgPword.
Press OK to select
Insert a 6 digit password twice
and press OK twice to confirm
Exit the programming mode
CHANGING THE RELAY LOCK TIME
It is possible to vary the relay lock timing (Min 01 seconds, Max 50 seconds)
OPERATION
Enter the programming mode
Scroll the menu using the UP or DN buttons
till option: Chg Time.
Press OK to select
Insert the 3 desired digits
and press OK twice
Exit the programming mode
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The programmer requests the Master Card
number
The buzzer will "bip" for a variable time,
according to how many access keys are stored
in memory (Max 8 min).
The buzzer will "bip" continuously for 2
seconds and will return automatically in
standby mode
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The programmer requests the password for
changing the Master Card
the buzzer will "bip" every second and the
programming LED will flash at the same timing
the buzzer will "bip" continuously for 2 seconds
and the module returns to standby mode
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The buzzer will "bip" continuously for 2
seconds
The buzzer will "bip" continuously for 2
seconds and will return automatically in
standby mode
DESCRIPTION
The buzzer will "bip" every 3 seconds and the
programming led will flash at the same timing
(programming mode)
The programmer requests the relay lock timing
The buzzer will "bip" continuously for 2 sec-
onds and will return automatically in standby