Speedaire Operating Instructions and Repair Parts List
Model 6Z899B
Troubleshooting Chart
Symptom
Possible Cause(s)
No material coming
1. Plugged hoses or material tube
from tank
2. Damaged regulator diaphragm
3. Incorrect hose connections
Air leak at tank lid
1. Damaged gasket
2. Dirty tank rim
3. Eyebolt knobs not tightened securely
Notes
Corrective Action
1. Check hoses and material tube
2. Check regulator for leaks. Replace diaphragm if
necessary
3. Check connections according to instructions
1. Replace gasket
2. Clean rim
3. Check tightness (See Operation)
Purge all air from tank before
adjusting eyebolt clamps
5