Kohler K-647 Guia De Instalacion página 7

Griferías monomando de fregadero de cocina
Ocultar thumbs Ver también para K-647:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Weight
Spray Hose
O-Ring
Valve Outlet
Hose
6. Connect the Spray Hose
Slide the weight onto the spray hose.
Verify that the hose ends are clean and that the O-ring is in place.
Fully engage the hose ends.
Extend and retract the spray hose to check for smooth operation.
Reposition the supply hoses if necessary.
7. Optional Water Temperature Limiting Adjustment
NOTE: Before adjusting the water temperature, ensure the handle is
turned all the way to the left. This is the maximum hot position.
Remove the plug button, setscrew, handle, and bonnet.
Reposition the indexer to stop the valve stem at the desired
maximum temperature.
Allow the water to flow through the spout and rotate the valve
stem to the full hot position to confirm the temperature setting.
Repeat the above procedures until the desired temperature is
reached.
Reinstall the bonnet and handle onto the faucet body. Secure the
handle with the setscrew.
Reinstall the plug button.
Kohler Co.
Plug Button
Setscrew
Bonnet
Indexer
Valve Stem
Splines
7
Handle
1048033-2-B
Tabla de contenido
loading

Este manual también es adecuado para:

K-r648K-649

Tabla de contenido