Display:
SETTINGS
Via the Menu key, you can adjust the desired settings. After pressing the menu, the display shows the following settings:
1.
Man Vol Out xxx%.
Adjust the manual volume output within the range of 0% to 100% by means of the Up/Down keys.
2.
Interval Set xxxS
Adjust the interval between each fog emission within the range of 1 to 100S by means of the Up-/Down keys.
3.
Duration Set xxxS
Adjust the duration of each fog emission within the range of 1 to 100S.
4.
Volume Out xxx%
Adjust the volume output during the timer function within the range of 0-100%
5.
DMX 512 #xxx
Adjust the DMX address for DMX control.
6.
Wind for Class
Adjustable fan speed for manual/timer mode.

TIMER CONTROL

Press the Timer key to activate the timer function. The display shows the adjusted interval and the device counts the seconds
down to "0". After that, the fog emission is triggered at the volume adjusted under "Timer Out". The duration depends on the
settings adjusted under "Duration Set". If you wish to deactivate the timer function, press the Timer key once more.
Manual control (100% output)
Press the Manual key for immediate triggering of the fog emission at 100 % volume. Let the Manual key
loose in order to stop the fog emission.
Manual control (locked)
Press the Lock switch for immediate triggering of the fog emission at the volume adjusted under "Volume Out". Press the
Volume switch once more in order to stop the fog emission.
DMX control
Connect the machine directly to a DMX controller or a DMX loop with multiple DMX effects. The machine uses a 3-pin XLR
connector for DMX connection.
Address Setup: Press the MODE button a number of times until Add appears on the display, with the UP / DOWN buttons the
start address may be set. The start address is defined as a first channel to which the machine will respond to. Check that there
are no overlapping channels used!
Channel
1
2
Note: It is necessary always lock the DMX loop with a 120 Ohm terminator for correct data transmission.
 
 
 
 
Function
Value
Smoke
000-255
Fan
000-255
Description
Output 0-100%
Speed 80-100%
4