DESCRIPTION
Thank you for choosing our product! In order to take the most of your welder, please read the following
instructions carefully:
These welding are, Inverter, portable welder, for covered electrode and TIG Lift in DC. It allows welding with rutiles,
basic, stainless steel. In TIG, it allows to weld most of metals except aluminium and alloys. It is protected for a use
on electric generators (230V /+- 15%).
POWER SUPPLY – START UP
• These machine are delivered with a 230V socket /16A plug type EEC7/7. Le GYSMI E200 PFC must be plugged on
a 230 V (50-60Hz) with earth. The GYSMI E200 FV integrate a « Flexible Voltage » system. It has to be on a
power supply variable between 110V and 240V (50 – 60 Hz) WITH
is shown on the machine, for maximal using conditions. Check that the power supply and its protection (fuse
and/or circuit-breaker) is compatible with the necessary current during use. In some countries, the change of plug
can be necessary to allow a use at maximal conditions. The welder must be installed so that the main plug is
accessible.
•
The start-up is done by pressing
The device turns into protection mode if the supply voltage is over 265V for the single-phase products
(the sсreen displays
range.
• These are A-class devices. They are designed to be used in an industrial or professional environment. In a
different environment, it can be difficult to ensure electromagnetic compatibility, due to conducted
disturbances as well as radiation.
•
The GYSMI E200PFC features primary regulation, it is recommended to use the cables supplied with the unit.
ELECTRODE WELDING (MMA Mode)
• Leave the machine connected to the supply after welding in order to let it cool down.
• Thermal protection: thermal protection indicator turns on and the cooling time is about 2 to 5 min
according to external temperature.
• Your machine is equipped with 3 specific functions to Inverters :
The Hot Start (adjustable mode depending on model, see below) increases the current at the beginning
of the welding.
The Arc Force (adjustable mode depending on model, see below) increases the current in order to avoid
the sticking when electrode enters in melted metal.
The Anti Sticking allows you to easily withdraw your electrode without damaging it in case of sticking.
Selection of MMA Mode and intensity setting:
- Select the MMA position
- Adjust the wished current (display
Hot Start & Arc Force adjustments:
Advice:
Low Hot Start: for thin metal sheets
High Hot Start for metals that are difficult to weld (dirty or oxidized parts)
TIG LIFT
The DC TIG welding requires a protective gas (argon).
Follow the steps as below :
1. Connect the earth clamp on the positive pole (+).
2. Connect a torch "valve" negative polarity (-).
3. Connect the pipe gas torch on the gas cylinder
4. Select TIG mode
5. Adjust the wished current (display
(
)
). Normal operation will resume
with the selector.
) using the key
Hot Start
Arc Force
using the selector button
) using the keys
earth.
when the voltage has returned to its nominal
.
E200 PFC
E200 FV
0
90%
Automatic
Automatic
(Ref. 044425)
.
.
The absorbed effective current (I1eff)
8