GB
SYNCHRONISM
The beams from a pair of photocell in a system with two pairs of photo-
cells that are close together could interfere on the other pair causing
malfunction; in this case it is advised to activate the synchronism
alternating power supply is available.
To activate the synchronism, cut the jumpers in both transmitters (deta-
il 5 fig. 1) and invert the power supply on one of the photocell pairs,
see figure 5. If it is not possible to activate the synchronism, then avoid
positioning the two receivers on the same side and the transmitters on
the other, and alternate the receivers and transmitters, fig. 6.
FINAL ADVICE
Do not perform any wiring or modifications to the connections prior to
having isolated the power supply.
The non-observance of the said instructions could prejudice the correct
function of the equipment.
TELCOMA decline any responsibility for possible malfunction and/or da-
mage due to their non-observance.
TELCOMA srl reserve the right to make modifications at any time they
deem necessary in order to improve the aesthetical and/or functional
aspect of the product.
if an