Adjusting the planting unit load

B
D
UN41-0434AM
The adjustment unit is usually mounted in position
(A1).
With the unit (A) in position (A1) the weight on the pack-
ing wheels can be reduced.
With the unit (A) in position (A2) the weight on the pack-
ing wheels can be increased.
The weight (load) to be applied to the packing wheels
is obtained by the combined action of the adjustment
units (A) and (B).

Adjusting the automatic safety release function

The automatic release is designed to protect the trans-
mission components from overloads (e.g. if the dispens-
er or ejector jams).
UN41-0454AM
For adjustments, proceed as outlined below.
1) Turn the ring nut (A) clockwise to increase the release
resistance (i.e. less sensitive).
English language
ADJUSTMENT INFORMATION
A1
A2
To adjust the transplanting unit load proceed as outlined
below.
1) As regards the position of the adjustment unit (A),
The device, installed on every planting unit, is already set
by the manufacturer during the testing stage, but can be
adjusted by the user according to requirements.
A
2) Turn the ring nut (A) anticlockwise to decrease the
29
turn the handwheel (C) and the handwheel (D) to ap-
ply the ideal weight to the packing wheels.
release resistance (i.e. more sensitive).