5.
Installation
• Prepare the machine to fit the fastening devices (holes, brackets, supports, etc.) of each sensor, then install the
sensor separating it from the relative transmitter.
• Prepare the cable protection devices (sheaths, ducts) on the machine.
• Position the junction boxes housing the transducers at a distance from the machine that takes into account the
total length of the sensor+extension cable connection.
R
emembeR that the length of the connection between the sensoR and the tRansmitteR should not be changed
this would Result in changes in instRument lineaRity and calibRation
With the machine stationary, make a first adjustment of the mechanical gap to approximately 1.5 mm.
• For sensors installed outside the bearing, this adjustment can be made using a thickness gauge
• For sensors installed inside the bearing support, it is advisable to measure the total depth of the hole using a
gauge and screw in the sensor so that the mechanical gap is approximately 1.5 mm
• Recommended probe case torque 10 N x m. For the first 10 threads, maximum torque 3 N x m.
.
,
as
15