5 - MAINTENANCE
(See General Warnings 9, 11,15 and 17 p.7)
CAUTION: Before removing the plastic cover, make sure the power is turned off to avoid any risk of injury or electric
shock
 User maintenance: Operates once a month the discharge of the water safety device to prevent scaling and
verify that it is not blocked. If this is not done, damage may be caused and the guarantee invalidated. For an
installation with a booster pump; before starting up, after a long period of disuse, turn the rotor following the advice in
tСОΝmanuПaМturОr'sΝТnstruМtТonsέ
 Maintenance by a qualified person:
1/ Remove the scale sludge. Do not scrape or hammer the lime scale deposited on the casing, as this may damage
the lining.
2/ Change the magnesium anode every 2 years or when its diameter is lower than 10 mm.
3/ Changing the shielded heating element or the anode requires the water heater to be drained and the joint changed.
DRAIN: Switch off the power and cold water and open the hot water taps before carrying out these operations. Refit
the heating element and tighten the screws smoothly (opposite screws in sequence), check for leaks the next day and
tighten if required.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or
its service agent.
Spare parts list: thermostat, thermal circuit breaker, joint, heating element, pilot light, the magnesium anode, the
connection cable. TСОΝРЮКrКntООΝrОqЮТrОsΝРОnЮТnОΝmКnЮПКМtЮrОr'sΝpКrtsΝtoΝЛОΝЮsОНέ
Advice to the user: When the water has a TH > 20°f, it is recommended that this be treated. When a softener is used,
the water hardness must remain above 15°f. In case of prolonged absence, especially in winter, drain your appliance
following the procedure.
6 - SCOPE OF THE GUARANTEE
The water heater must be installed, used and maintained according to best practice and conform to the standards in
force in the country in which it is installed and to the instructions contained in this document. In the European Union
this appliance is covered by the statutory guarantee accorded to consumers in accordance with directive 1999/44/CE.
This guarantee comes into force when the appliance is delivered to the consumer. In addition to the legal guarantee,
certain items are covered by an extra guarantee relating only to the free exchange of the tank and of components
accepted as defective. It does not include the cost of replacement or carriage. Refer to the table below. This
commercial guarantee does not affect your statutory rights. It applies within the country where the product was
acquired, provided it is also installed in the same country. The dealer must be informed of any damage before the
product is exchanged under guarantee and the appliance will remain available for inspection by experts from the
insurance company and the manufacturer.
Statutory
Extra commercial guarantee on tanks except for electrical components
To claim under guarantee, contact your installer or dealer. If necessary, contact: ATL INTERNATIONAL
Tel:(33)146836000, Fax (33)146836001 58 avenue Général Leclerc 92340 Bourg-la-Reine (France) who will inform you
of what you should do. The guarantee applies only to examine products which are accepted as faulty by the company
underwriting the guarantee. It is essential that products should be retained for inspection by them. Exclusions: Wear
partsμΝ maРnОsТumΝ anoНОs...έϋquТpmОntΝ аСТМСΝ МannotΝ bО assessed (access difficult for repair, maintenance or
assessment). Equipment exposed to abnormal environmental conditions: frost, bad weather, water which is abnormally
aggressive or outside drinking standards, electrical supply with large spikes. Equipment installed without observing
current standards in the country of installation: the absence or incorrect fitting of safety devices, abnormal corrosion due
to incorrect water fitments (iron/copper contact), incorrect earthing, inadequate cable thickness, non-observance of the
connection drawings shown in these instructions. Equipment not maintained in accordance with these instructions.
Repairs or replacement of parts or components in the equipment not carried out or authorised by the company
responsible for the guarantee. Changing a component does not extend the life of the guarantee.
CAUTION: To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and
pressure protective equipment supplied with the water heater (pressure relief devices). Install the valve into an opening
provided for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve will exit
only within 15cm above or at any distance below the structural floor and cannot contact any live electrical part. The
discharge opening must not block or reduce in size under any circumstances.
Type / Reference:
Serial number :
Name and address of
customer
11
2 years all parts
+ 1 year
Dealer stamp