brilli 20752-000 Instrucciones Importantes De Seguridad página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION (POWER-CORD METHOD)
Part Description
1
Direct-Wire Cavity Access Plate Screw
2
Direct-Wire Cavity Access Plate
3
Wire Terminals
4
Wire
5
Fixture Assembly
6
End-to-End Port Cover
7
Mounting Screws
8
End-to-End Row connector
9
Romex Bushing
10
13'' Connector Cord
11
5'Power Cord
1. Remove fixture from the carton and check for any shipping
damage. Note: TURN OFF POWER AT CIRCUIT BREAKER BOX!
WIRING AND FIXTURE OPERATION CAUTION: Connect fixture
to supply wires rated for at least 90°C (194°F). Assistance may be
required to support fixture during installation.
2. Determine location of your first fixture. Make sure the mounting
location is within 5 feet of an electrical outlet.
3. Position the fixture housing against the mounting surface and
with a pencil, mark the screw hole locations to be located at the
narrow section of the keyholes (See Fig.1).
Fig.1
4. Using a drill with a 1/8" drill bit (not included), make two small
pilot holes at the marked locations. (Note: do not drill entirely
through mounting surface).
5. Partially install the provided mounting screws ⑦ with a Phillips
screwdriver (not included).
6. Position the keyhole mounting holes over the screw heads and
slide the fixture until the screw heads are over the narrow section
of the keyholes. Finish tightening the screws to secure the fixture.
7. If using only one fixture skip to Step 9.
8. If connecting more fixtures, please repeat steps 3-6.
WARNING: Do not link together more than six units of fixtures on
any single run.
Note: The distance between fixtures cannot exceed the length of
the included 13" connector cord ⑩ (See Fig.2) or end-to-end row
connector ⑧ (See Fig.3).
To route your fixtures around a corner, simply install a fixture near
the corner and route the 13" connector cord ⑩ around the corner
to connect the next fixture.
Fig.2
Qty
1
1
3
3
1
2
2
1
1
1
1
For Customer Assistance:
www.evolutionlightingllc.com
Made In China
3
Fig.3
9. After installation completed, place the End-to-End Port Cover
on the output port (See Fig.4).
Fig.4
10. Plug in 5' power cord
outlet (See Fig.5).
Fig.5
11. When all fixtures have been properly installed, ensure all of the
fixtures in the chain have been securely connected.
WARNING: RISK OF ELECTRICAL SHOCK
Do not use 5' power cord
wiring the fixture! Use only one method to power the fixture.
12. Turn on power at the circuit breaker box and verify that fixture
functions properly. If fixture does not turn on, verify that the rocker
switch on each fixture is in the "on" position.
to a grounded three-prong electrical
accessory when also direct-
Tabla de contenido