CENTRALISATION
Two radio centralisation modes are possible according to the number of modules to be controlled and the distance between
the various modules:
• Direct mode: up to four modules per pushbutton
• Radio bus mode: unlimited number of modules
Refer to the transmitter instruction booklet or the "Radio Memo" or go to the www.yokis.com website for more information.
MODULE CONFIGURATION TABLE
----- time configuration ------
Number of
Presses (1)
Time (4)
11
2 minutes
12
4 minutes
13
8 minutes
14
15 minutes
15
30 minutes
16
60 minutes (1 hour)
17
120 minutes (2 hours)
18
240 minutes (4 hours)
19
unlimited
(1) Short press sequences on transmitter pushbutton or
'connect' tab of module.
(2) Confirmation reply with flashes at end of press
sequence.
(3) To switch the function on and off alternatively (activa-
tion and deactivation switch)
(4) The time may be set in minutes (default) or in
seconds.
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256 -
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The material must be used
according to the instructions provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence,
anomalous use or incorrect installation. In all cases, the warranty only includes replacement of faulty products. No compensation for loss or damage may
be claimed.
DS1054-011D
Reply (2)
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
For technical information, go to www.yokis.com or call:
Fax: +39 011.24.00.296
------ function configuration -------
Number of
Presses (1)
Function
20
Relay mode (no dimmer function)
21
Lock configurations
22
Flashing mode (3)
23
Unlock configurations (with automatic
rearming after 1 hour)
24
Disable switch-off warning (3)
25
Set time in seconds (4)
26
Set time in minutes (4)
27
Minimum brightness level setting
28
Restore minimum default brightness level
29
100% or one press memory mode
30
Full reset to default settings
35
Store in case of blackout mode
P10
Reply (2)
10 flashes
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
2 flashes
5 flashes