9. Window technology

fail-safe switch
The output is only enabled in case of a damping between 10 mm
and 15 mm (zone 2, see 12. Technical data, page 20).
In the zones 1, 3 and 4 the output remains switched off.
The safe switching off distance is 30 mm.
Note
The enable zone is specified for the described environmental condi-
tions or conditions of use (please see 12. Technical data, page 20).
Conditions of use outside the given technical data result in a differ-
ent enable zone.

10. Response times

(removal from the enable zone)
Change of zones
from
to
2
3
2
1
2
4
18
1
2
enable
zone
0
10
Response time (max.)
80 ms
360 ms
20 ms
3
4
15
30