INSTRUCTION ON MOUNTING AND USE
GB
Check also the drawings on the initial pages with the alphabetical
and numerical references in the explanatory text.
Closely follow the instructions in this manual. We cannot
accept liability for any faults, detriment or fire damage to the
appliance due to non-compliance with the manual's
instructions. Installation and electrical connections must be
executed by a qualified technician. You should affix the hood
to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard. Do not install it inside a cupboard.
Attach it to the wall using the anchors provided:( Fig. 3 diameter
12, Fig. 5 diameter 8.)
Installation
The cooker hood must be placed at a minimum distance of 65
cm from the cooking plane for electric cookers and 75cm for
gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface
mounting only. Do not fix chimney flue to furniture or fly over
shelves unless the chimney flue can be easily removed, in
case maintenance is ever required.
Use
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe not supplied).
If cooking fumes and vapours cannot be externally discharged,
the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
Electrical connection
Make sure that there is a power socket near the hood and
that the system has a 30 mA differential. The mains voltage
must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it
does have a plug, connect the hood to an accessible
approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum
contact opening of no less than 3 mm (accessible). This
installation and electrical connection must be executed by a
qualified technician.
Operation
A
C
B
With the hood switched off, pressing any key will activate
the control panel in stand-by mode. The symbols are backlit
by a white light, allowing you view and select the desired
function.
Pressing one of the keys again will start the corresponding
function, and its symbol will light up. After all functions have
been switched off, the control panel will remain in stand-by
mode for around 30 seconds and then switch off automatically.
TSL2
D
E
F
A: Light ON/OFF key: press this touch sensor to switch on
or off the lights of the hood.
C: Motor ON/OFF key (4 speed): press this touch sensor
to switch on the hood extractor fan at the same speed as it
was when last switched off. Use the „D" and „B" keys to
vary the speed (power) of extraction.
B: Decrease extraction speed (power) key: press this
touch sensor to reduce the extraction speed of the hood.
D: Increase extraction speed (power) key: press this
touch sensor to increase the extraction speed of the hood.
E: Timer key: when this touch sensor is pressed,
independently of the extraction speed selected, the timer
function will be activated. Press once to set the timer for 5
minutes, press a second time for 10 minutes and a third time
for 20 minutes. During this phase, the „E" symbol will flash.
To reset the timer, press the motor key, „C"
F: Reset filters key: press this touch sensor to reset the
signal that warns that the metal grease filter (1) is saturated
and the charcoal filter (2) should be replaced.
(1)
After 40 hours of using the hood, the „F" symbol
will flash to indicate the necessity of cleaning the
metal grease filters.
(2)
After 120 hours of using the hood, the „F" symbol
will light up to indicate the necessity of replacing
the activated charcoal filters.
Sensor function: pressing the „B" and „D" keys at the
same time will activate the sensor. In this mode the extraction
speed sets itself automatically and the „B e D" key flashes
intermittently. To return to manual operation, press either the
„B" or the „D" key.