3.2.2 Connection Diagramam
+24 V DC - Brown cable
0 V DC - Blue cable
GND - Green/yellow cable
3.2.2.1 Example of Connection LSP With Safety Relay
+ 24 V DC
24 V DC
1
2
NC
0 V DC
3
4
NC
5
GND
LSP
Emitter
* Optional feedback loop to monitor
0 V DC
contactors or the expansion modules
+ 24 V DC
24 V DC
1
2
NC
0 V DC
3
4
NC
5
GND
LSP
Emitter
* Optional feedback loop to monitor
0 V DC
contactors or the expansion modules
+24 V DC
NC
0 V DC
NC
GND
Emitter
Figure 3.9: Connection diagramam
+24 V DC
1
OSSD 1
OSSD 1
2
OSSD 2
OSSD 2
4
0 V DC
3
GND
5
LSP
Receiver
+24 V DC
1
OSSD 1
OSSD 1
2
OSSD 2
OSSD 2
4
0 V DC
3
GND
5
LSP
Receiver
Figure 3.10: Example of connection
Installation and Connection
+24 V DC - Brown cable
+24 V DC
Output 1 - White cable
OSSD 1
0 V DC - Blue cable
0 V DC
Output 2 - Black cable
OSSD 2
GND - Green/yellow cable
GND
Receiver
CPW17
A1
S1
S2
S3
A2
CPW22
A1
S12
S14
S21
S10
S13
A2
LSP | 17